Example for DIP switch setting

The table below shows the various setting options. The position of S1
determines whether day or week function was selected.
Preset default
Day function (S1 = OFF)
setting:
No Astro correction time (S6 = OFF)
No reverse function (S7 and S8 = OFF)
Day
Y123$5678X
Example of the DIP switch position for North-Rhine Westphalia.
For other states, please see pages 58 and 59.
For DIP switch S6, see page 57, for S7 and S8 see page 60.
Week
Y!wert678X
DIP switches S2 – S5 do not have any function for this setting.
For DIP switch S6, see page 57, for S7 and S8 see page 60.
The respective DIP switches are located on the rear panel of the control.
Special functions
- 61 -
G/S functions
Your control features two additional useful functions:
1. Broken glass sensor (G)
The function "broken glass sensor" is only activated in the auto-
matic operation.
2. Sun protection (S)
The function "sun protection" can only be operated in the automatic
operation within the previously programmed up and down times.
NOTE!
v v
Standard length of the Lux sensor cable
Standard length of the broken glass sensor cable
Cables of up to 5 m length can be delivered for both functions.
G
G

General

– 1 or 2 m
– 1 or 2 m