Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Trotec TP6 MultiMeasure Professional Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für TP6 MultiMeasure Professional:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

13. Technical Data

Temperature range
Resolution
Target display
-50 °C to 20 °C (-58 °F to 68 °F)
Accuracy
21 °C to 300 °C (69 °F to 572 °F)
301 °C to 1,000 °C (573 °F to 1,832 °F)
Emission factor
Reaction time
Spectral sensitivity
Optical resolution (D:S)
Smallest measurement spot ø
Automatic switch off
Operating conditions
Storage conditions
Power supply
Weight
Dimensions
When the unit is moved from a warm location to a cold location (or vice versa), this relocation can lead to condensation formation
on the electronic measuring equipment. This physical effect, which cannot be prevented for constructional reasons, invariably leads
to deviations in measurement. The unit requires an "acclimatisation time" of approx. 15-30 minutes, depending on how high the tem-
perature differences were, before the measuring process can be continued.
B 09
-50 °C to + 1,000 °C (-58 °F to +1,832 °F)
0.1 °C (0.1 °F)
Laser class 2 (II), 630 ~ 670 nm, < 1 mW
± 2.5 °C (4.5 °F)
±1 % of measured value
±1.5 % of measured value
adjustable from 0.10 to 1.0
< 150 ms
8 ~14 µm
30:1
25.4 mm
after about 10 seconds
0 °C to 50 °C (32 °F to 122 °F), 10 % to 90 % r.h.
-10 °C to 60 °C (-2 °F to 140 °F), < 80 % r.h.
9V battery
163 g
104 x 43 x 146 mm
Operating manual – English

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis