5. INSTALLATION

5.1 Setting up and mounting

The speaker system can be set up as desired without the mounting bracket. For this purpose unscrew the
locking screws and remove the mounting bracket. The location must be solid, plane, anti-slip, vibration-free,
oscilation-free, and fire-resistant. The installation area must hold a minimum point load of 5 times the
system's load (e.g. weight 20 kg - point load 100 kg).
For using the speaker system as wall speaker it can be fastened to the wall via the mounting bracket. The
installation of the device has to be built and constructed in a way that it can hold 5 times the weight for 1
hour without any harming deformation.
Please note: When using this speaker system in public or industrial areas, a series of safety instructions
have to be followed that this manual can only give in part. The operator must therefore inform himself on the
current safety instructions and consider them.
When rigging, derigging or servicing the device staying in the area below the installation place, on lighting
bridges, under high working places and other danger zones is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.
The device should be installed outside areas where persons may walk by or be seated.
IMPORTANT! Overhead rigging requires extensive experience, including (but not limited to) calculating load
capacity, installation material being used, and periodic safety inspection of all installation material and the
device. If you lack these qualifications, do not attempt the installation yourself, but instead use a professional
structural rigger. Improper installation can result in bodily injury and or damage to property.
Caution: Devices in hanging installations may cause severe injuries when crashing down! If you have
doubts concerning the safety of a possible installation, do NOT install the device!

5.2 Attachment to the wall

The device must only be installed absolutely planar at a vibration-free, oscillation-free and fire-resistant
location. Make sure that the device is installed absolutely planar by using a water-level.
The device must be installed out of the reach of people.
This device is only allowed for an installation via the mounting bracket. In order to safeguard sufficient
ventilation, leave 50 cm of free space around the device.
The device must always be installed via all fixation holes. Do only use appropriate screws and make sure
that the screws are properly connected with the ground.
The durability of the installation depends very much on the material used at the installation area (building
material) such as wood, concrete, gas concrete, brick etc. This is why the fixing material must be chosen to
suit the wall material. Always ask a specialist for the correct plug/screw combination indicating the maximum
load and the building material.