Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Measures On The Installation Site; Safety Equipment - Behncke EWT 80-40 Installationsanweisung

Vorschau ausblenden Andere Handbücher für EWT 80-40:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Safety
temperature limiter and/or flow control) strong overheating of the electric heat
exchanger is possible.
The installation of a flow control as an additional safety device is
recommended.
It prevents the heating resistor from burning out during water standstill.
If the electric heat exchanger is installed more than 0.5 m below the surface of the
bathwater, the safety pressure limiter becomes ineffective.
The installation of a flow control is prescribed in this case as an additional
safety device.
The electric heat exchanger might be damaged.
If dripping water falls onto the outer skin or if metal particles enter the electric heat
exchanger, the risk of contact corrosion exists.
take care
1.5

Safety Measures on the Installation Site

The electric heat exchanger is to be installed in a frost-proof room with a mounting
device made of plastic or stainless steel.
Please ensure that the maximum operational overpressure of 3.0 bar is not excee-
ded.
The electric heat exchanger or the environment can be damaged.
Please check the electric heat exchanger and its connections for tightness and
visible damage once a week during operation.
take care
The danger of combustion exists.
In the case of a failure of the safety pressure limiter and the safety temperature
limiter, strong overheating of the electric heat exchanger is possible.
Do not store any combustible materials in the environment.
take care
The installation of a flow control as an additional safety device is recommended.
It prevents the heating resistor from burning through during a water standstill.
The electric heat exchanger can be damaged.
The electric heat exchanger may only be put into operation if it has been ensured
that the electric heat exchanger is continuously supplied with water during operati-
on. The water throughput must be at least 1000l/hour.
take care
1.6

Safety Equipment

30

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ewt 80-70Ewt 80-t

Inhaltsverzeichnis