4.1 Cable extensions

When operating with a six wire measuring amplifier the cable can be extended
without any ill effects (maximum 200 meters).
The prerequisite for this is the use of a high grade, low capacitance
measurement cable. The supplementary sense leads (HBM colors gray and
green) then assess the voltage at the transducer connection and feed it back
to the six wire measuring amplifier. This regulates the voltage so that it
reaches the transducer loss free.
5

Mounting

The transducer has a clamping shank Ø8
entire length of the metallic enclosure tube.
It must be clamped so that the enclosure tube is not distorted by clamping
forces. The fitted connection cable must not be subjected to loads by pulling
or vibration.
The contact force of the probe is dependent on the installation site.
In the event of loading due to acceleration, e.g. due to vibrations, oscillations
etc., please refer to chapter 5.5 "Frequency and acceleration limits".
NOTE:
Never apply force to the plastic potting compound during mounting. No
torsional load must be applied to the plastic connection or the metal
housing.