Herunterladen Inhalt Inhalt Diese Seite drucken

Shelf Holders; Installation; Installation Location - AEG Electrolux SANTO Z 9 18 40-5 i Gebrauchs- Und Einbauanweisung

Vorschau ausblenden Andere Handbücher für SANTO Z 9 18 40-5 i:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Shelf holders

Your appliance is equipped with shelf
retainers that make it possible to
secure the shelves during transporta-
tion. To remove them proceed as fol-
lows:
Move the shelf retainers in the direc-
tion of the arrow, raise the shelf from
the rear and push it forward until it
is freed and remove the retainers.

Installation

Installation Location

The appliance should be set up in a well ventilated, dry room.
Energy use is affected by the ambient temperature. The appliance should
therefore
– not be exposed to direct sunlight;
– not be installed next to radiators, cookers or other sources of heat;
– only be installed at a location whose ambient temperature corresponds to
the climate classification, for which the appliance is designed.
The climate classification can be found on the serial plate, which is located
at the left on the inside of the appliance.
The following table shows which ambient temperature is correct for each
climate classification: each climate classification:
Climate classification
If installation next to a source of heat is unavoidable, the following mini-
mum clearances must be maintained at the sides of the appliance:
– for electric cookers 3 cm;
– for oil and coal fired ranges 30 cm.
If these clearances cannot be maintained a heat insulating pad is required
between the cooker and the refrigeration appliance.
If the refrigeration appliance is installed next to another refrigerator or free-
zer a clearance of 5 cm at the sides is required, in order to prevent the for-
mation of condensation on the outside of the appliance.
SN
N
ST
T
A
B
C
for an ambient temperature of
+10 to +32 °C
+16 to +32 °C
+18 to +38 °C
+18 to +43 °C
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis