Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

TECHNICAL DATA

Dimensions
Weight
Capacity (water temp. 15 °C)
Water efficiency
Electrical supply
Total power consumption
Operation period
Start pressure
Stop pressure
Sound level when installed cupboard
Environmental specifications
air temperature
relative humidity
Requirements of feed water to the RO 400:
Supply feed
Supply pressure at the inlet valve during operation
Water temperature
Chemical requirements*:
Conductivity
/salt
/chloride
cloudiness
turbidity
pH
calcium: Ca
2+
magnesium: Mg
2+
/hardness
iron: Fe
2+
iron: Fe
3+
manganese: Mn
2+
COD-MnO 2
Microbiological requirements
Heterotrophic bacteria (48 hour test count)
Coliform bacteria
E.coli
* higher values require an extra prefilter.
68
height 446 mm
depth 470 mm
width 225 mm
29 kg when supplied
33 kg when filled with water
2.5 (± 0.4) litres/minute
approx. 50 % during operation
230 V, 50 Hz, 10 A, earthed socket/110 V, 60 Hz, 10 A
530 W
Unlimited (though with 2 minutes automatic flushing every 15
minutes when in operation)
When the water pressure in the purified water hose from the
RO 400 has fallen below 3 bar (300 kPa)
When the water pressure in the purified water hose from the
RO 400 has built up to over 4.5 bar (450 kPa) during operation.
< 60 dB(A)
2 – 30 °C
25 – 95 %
> 10 l/minute
150 – 1000 kPa (1,5 – 10 bar)
2 – 30 °C
< 200mS/m
< 1.500 mg/l
< 900 mg/l
slight/ distinct
< 1 FNU
4 – 10
< 140 mg/l
< 20 °d
< 5 mg/l
< 0.30 mg/l
< 0.8 mg/l
< 10 mg/l
1000/ml
1000/100 ml
100/100 ml

Werbung

Inhaltsverzeichnis
loading