Eliminating minor faults yourself

Before you call customer service:
Please check whether you can eliminate the fault yourself based on the following
information.
Customer service will charge you for advice – even if the appliance is still under
guarantee!
Fault
Temperature differs greatly
from the set value.
The light does not work.
Bottom of the refrigerator
compartment is wet.
The temperature in
the refrigerator
compartment is too cold.
The refrigerating unit
is switching on more
frequently and for longer.
Possible cause
The bulb is defective.
Light switch is jammed.
The condensation channel
or drainage hole are blocked.
Temperature has been set
too low.
Appliance opened
frequently.
The ventilation openings
have been covered.
Remedial action
In some cases it is adequate to switch off
the appliance for 5 minutes.
If the temperature is too high wait a few hours
and check whether the temperature has
approached the set value.
If the temperature is too low check
the temperature again the next day.
Replace bulb. Fig. ,/B
1. Switch the appliance off.
2. Pull out mains plug or switch off fuse.
3. Remove bulb cover from the rear.
4. Change the bulb.
(Replacement bulb: 220–240 V a.c., E14
bulb holder, see defective bulb for
wattage.)
Check whether it can be moved. Fig. ,/A
Clean the condensation channel
and the drainage hole. See chapter Cleaning
the appliance. Fig. +
Increase the temperature.
Do not open the appliance unnecessarily.
Remove obstacles.