22
en |
Pin assignment
No.
Connections
1
+V
2
0 V
3/4
aLSN1/bLSN1
5
+V
6
0 V
7/8
aLSN2/bLSN2
9/10
11/12
+12 V/0 V
Control output S1
13/14
+12 V/0 V
Control output S2
15/16
+12 V/0 V
Control output S3
17/18
+12 V/0 V
Control output S4
19/20
+12 V/0 V
Output
21/22
SP
23/24
SP
25/26
SP
27/28
SP
29/30
SP
31/32
PL 1
33/34
SP
35/36
PL 2
37/38
SP
39/40
PL 3
41/42
SP
43/44
PL 4
45/46
SP
47/48
49/50
PL 5
51/52
SP
53/54
PL 6
55/56
SP
57/58
WT
59/60
SP
F.01U.076.548 | V3 | 2008.10
power supply 9.0 to 30 V, 1 and 5 connected internally
power supply 0 V, 2 and 6 connected internally
LSN incoming
power supply 9.0 to 30 V, 5 and 1 connected internally
power supply 0 V, 6 and 2 connected internally
LSN outgoing
– Earth inputs for cable shield (if available), 9 and 10 connected internally
– Cable shield from NBS 10, (wire color: 10 = white/green and brown/green)
+12 V/0 V switched minus potential, maximum output current 20 mA
– e.g. activation of relay module
– Block-type lock display LED1 "BLL" at NBS 10, (wire color: 11 = red, 12 = pink)
+12 V/0 V switched minus potential, maximum output current 20 mA
– e.g. activation of relay module
– Block-type lock display LED2 "BLA" at NBS 10, (wire color: 13 = green, 14 = gray)
+12 V/0 V switched minus potential, maximum output current 20 mA
e.g. activation of relay module
+12 V/0 V switched minus potential, maximum output current 100 mA
– e.g. activation of relay module
– Block-type lock magnet "BSM" at NBS 10, (wire color: 17 = yellow, 18 = blue/red)
Power supply for external users, output current maximum 100 mA
Free distributors for looping through, 21 and 22 connected internally
Free distributors for looping through, 23 and 24 connected internally
Free distributors for looping through, 25 and 26 connected internally
Free distributors for looping through, 27 and 28 connected internally
Free distributors for looping through, 29 and 30 connected internally
Primary line for connection of detector zone 1
e.g. connections for looping an external terminal resistance
Primary line for connection of detector zone 2
e.g. connections for looping an external terminal resistance
– Primary line for connection of detector zone 3
– Block-type lock primary line at NBS 10, (wire color: 39 = black, 40 = blue)
– Coded arming device
e.g. connections for looping an external terminal resistance
– Primary line for connection of detector zone 4
– Coded arming device
e.g. connections for looping an external terminal resistance
Earth inputs for cable shield (if available), 47 and 48 connected internally
– Primary line for connection of detector zone 5 or
– Connection of line-fed glass break detectors
– Block-type lock tamper detector zone at NBS 10, (wire color: 49 = white,
50 = brown)
e.g. connections for looping an external terminal resistance
– Primary line for connection of detector zone 6
– Connection of line-fed glass break detectors
e.g. connections for looping an external terminal resistance
Connection of optional wall tamper contact. If the wall tamper contact
is not connected, the WT bridge (57 + 58) remains plugged in.
Free distributors for looping through, 59 and 60 connected internally