Please read the product description prior to installing the unit.
Please check that the product is suitable for your application
without any restrictions.
If the operating instructions or the technical data are not
adhered to, personal injury and/or damage to property may
occur.
Please check in all applications that the product materials (see
Technical data) are compatible with the media to be mea-
sured.
For gaseous media the application is limited to max. 25 bar.

1. Function and features

The pressure sensor detects whether a preset value has been reached
or not and indicates this by a switched signal.
In addition a row of LEDs signals the current system pressure and the
switch point (both in 10% steps).
system pressure
Applications (type of pressure: relative pressure):
Order no.
PB5xx0
PB5xx1
PB5xx2
PB5xx3
PB5xx4
PB5xx6
PB5xx7
12

Safety instructions

switch point
Measuring range
0 ... 400 bar
0 ... 250 bar
0 ... 100 bar
0 ... 25 bar
0 ... 10 bar
0 ... 2,5 bar
0 ... 1 bar
= lit LED
= flashing LED
Permissible
overl. pressure
600 bar
400 bar
300 bar
100 bar
50 bar
20 bar
10 bar
Bursting
pressure
1000 bar
850 bar
650 bar
350 bar
150 bar
50 bar
30 bar