Initial set up and operation:
1. After connection to mains power, 60 seconds is required to warm up. The LED
indicator and lighting stay on approximately 60 seconds.
2. Please turn the LUX setting to maximum (clock wise) and the TIME setting to
minimum (counter clock wise). Walk under the product until the light comes up. This
checks the operation of the detector and the detection range. Under test mode, the
LED indicator and lighting will be turned on for 3 seconds when at each movement
detected
3. Check the detection range by performing a walk-test. Adjust the mounting
location/height if required.
4. Turn the Time and Ambient Light (LUX) control to the desired positions.
5. The detector is now in Auto Mode and will operate according to the preset time and
ambient light (LUX) adjustments. Once activated, LED indicator and lighting will
remain on until timer out.
6. Lights Permanently Off: Turn the power switch off or unplug the AC plug.
Figure J