Adjustments:
1. TIME:
The time can be set variably from 3 sec till 30 min. Timer starts counting from the last
detected movement. When there is still movement in the detecting area, the LED
indicator and the light will remain on and the timer will keep resetting. (Figure B)
Figure B
2. SENS:
Field of view: The angle of detection is 90°. The sensor has a range of detection of 8m at
a mounting height of 2.4m at 20°C. (Figure C+D).
Figure C
3. LUX:
The adjustment controls the sensitivity to the background light level at which the unit will
operate automatically. It may be set to any level between 5 Lux and full daylight. The unit
will operate when it senses movement and the ambient light is at or below the set level.
(Figure E).
Figure E
4. TEST:
Turn the LUX control clockwise to its end position 'sun' -symbol and the TIMER control
counter clock wise to its minimum position. When now the detector is activated by
movement, the red LED and the light remain ON for 3 sec. Now you can perform a walk-
test.
Figure D