60 MΩ
Open circuit voltage: 0,4 V
Audible Continuity
Range
Resolution
0.1 Ω
Buzzer
Open circuit voltage: -1,1 ~ -1,3 V
Overload protection: 250 V DC or AC RMS
Diode Testing
Range
Resolution
Diode
0.001 V
Forward DC current ~ 1 mA
Reversed DC voltage ~ 1.5 V
Capacitance Measurement
Range
6 µF
60 µF
600 µF
6 mF
60 mF
Overload protection: 250 V DC or AC rms.
4. Operating Instruction
-
If the current under measurement is higher than the selected value for a long period, overheating may
take place, compromising the safety and operation of inner circuits.
-
Do not measure currents on high-voltage conductors (>600 V) to avoid risks of discharge and/or
incorrect reading.
AC current measurement
Make certain that all test leads are disconnected from the meter terminals.
-
Set function switch to A~ range.
-
Clamp the current transducer (jaw) around one of the conductors under test. Make sure that the clamp
jaw be perfectly closed.
-
Read the display value.
-
For manual Range adjustment, press the range-key: RAN
-
To turn back to Autorange press and hold the RAN key.
-
At zero compensation the display might show 30 Digits.
It will not affect the measured value
INRUSH AC current measurement
-
Set function switch to A~ range.
-
Press the SEL key to enter Inrush current measurement.
-
The display reading is empty: ----
-
Clamp the current transducer (jaw) around one of the conductors under test. Make sure that the clamp
jaw be perfectly closed.
-
Turn on the item under test.
-
Read the Inrush current value in the display.
-
To make new measurement press and hold the SEL-key to return first to normal measurement and then
press SEL kea again to enter INRUSH current measurement.
-
For manual Range adjustment, press the range-key: RAN
-
To turn back to Autorange press and hold the RAN key.
DC current measurement
Make certain that all test leads are disconnected from the meter terminals.
-
Set function switch to A= range.
-
Open and close jaw for several times and wait till the display shows a constant reading
0.1 MΩ
Overload protection: 250 V DC or AC RMS
Built-in buzzer will sound, if resistance is lower than 30 Ω
Displaying approximate forward voltage of diode
Resolution
0.001 µF
0.01 µF
0.1 µF
1 µF
10 µF
± (2% + 5 digits)
Fuction
Fuction
Accuracy
<2 µF ± 4.0% + 5 digit
else
± 4.0% + 3 digit