2. Description
1) Transformer jaws
2) LED Lamp
3) Panel
4) Trigger
5) SEL switch
Keypad
HOLD/B.L.-key:
Fixes the display on the current value and memories it (short press).
A second short press returns the clamp meter to normal mode.
Press and hold to turn on backlight. If the rotary switch set to A,
the LED flashlight turn on additionally.
SEL-key:
Selection of the DC (default) or AC mode: press on the key, the beep sounds briefly.
This key is operative in V range.
Select between normal AC A and INRUSH current measurement.
ZERO in A DC current measurement.
Selection between Ohm, Diode and Continuity test.
MIN/MAX-key:
For switching between minimum, maximum and differential value
measurement
RAN-key:
Selection of the automatic (default) or manual mode
HZ/% key:
Select Hz or Duty Cyle (%) measurement in A=, A~ and V=~ measurement
Transformer jaws
Pick up the current flowing through the conductor.
Terminals
INPUT :
terminal receiving the red lead for voltage, resistance and continuity measurements
COM:
terminal receiving the black lead for voltage, resistance and continuity measurements
6) MIN/MAX button
7) RAN switch button
8) LCD
9) COM jack
10) INPUT jack
12
11) HZ/% button
12) HOLD and B.L. button
13) Rotary selector
14) Off power switch
15) Polarity Indication