10.1 Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
socket.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage regu-
larly. Ensure that the connection cables are disconnect-
ed from electrical power when checking for damage.
Electrical connection cables must comply with nation-
al provisions. Only use connection cables of the same
designation.
The printing of the type designation on the connection
cable is mandatory.
10.2 Connection type
Safety information for replacing damaged or defective
mains connection cables
Connection type Y
If it is necessary to replace the mains connection ca-
ble, this must be done by the manufacturer or their rep-
resentative to avoid safety hazards.
11. Cleaning
Danger!
Disconnect the mains plug before carrying out any
cleaning work.
• Keep protective devices, air vents and the motor
housing as free of dust and dirt as possible. Rub
the device clean with a clean cloth or blow it off with
compressed air at low pressure.
• We recommend that you clean the device directly
after every use.
• Clean the device at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
22 | GB
products or solvents; they could attack the plastic
parts of the device. Make sure that no water can pen-
etrate the interior of the device. Water penetrating an
electric device increases the risk of an electric shock.
12. Maintenance
Filter change (Fig. 6 - 7)
m Attention! The filter may only be changed after un-
plugging the mains plug.
• Remove the rear cover (2) by pulling it.
• Now the external filter (6) and the inner filter (7) can
be removed.
• The external filter (6) can be blown out.
• The inner filter (7) can be blown out (only to be car-
ried out outdoors!) or rinsed. The filter must be com-
pletely dry before putting it back in.
• An arrow is imprinted on the external filter (6) which
shows the air flow direction. Ensure that the filter is
inserted in the correct direction (Fig. 7).
Service information
With this product, it is necessary to note that the follow-
ing parts are subject to natural or usage-related wear,
or that the following parts are required as consumables.
Wearing parts*: Filter
* may not be included in the scope of delivery!
Connections and repairs
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the event
of any queries:
• Type of current for the motor
• Machine data - type plate
• Motor data - type plate
Spare parts and accessories can be obtained from our
Service Centre. To do this, scan the QR code on the
front page.
13. Storage
• Store the product and its accessories in a dark, dry
and frost-free place that is inaccessible to children.
The optimum storage temperature lies between 5
and 30 ˚C.
• Store the product in its original packaging.
www.scheppach.com