(2) Possible application

In potentially explosive environments, transport ventilator ComPact 1500 EX is the right choice. It
draws off dangerous gases safely and quickly. The housing made of a robust ABS carbon plastic
passes voltage into the floor and thus prevents static charges and for this reason dangerous sparking.
The housing and motor sealing is in keeping with the high protection class IP65 and offers an effective
protection against dust and water.

(3) Operation

Connect the unit to an earthed socket and set to switch A to ON. Check correct operation before
leaving the unit unattended. Do not move or carry the ventilator during operation. Observe the
direction of air. It is marked by an arrow B on the housing.
Special features in explosion-proof areas:
Installation conditions and different hazardous areas have to be observed.
Connect device to explosion-proof power socket only.
Only use antistatic air hoses and ground them, when required.
Accessories
Please use suitable accessories only !
For use in non-explosive areas you can use the following accessories:
1450290
Connection adapter from 230 CEE to 230 V shockproof plug
1250065
Air hose 7.6 m. diam. 205 mm
1250061
Dust bag (dust class M)
For use in explosive areas you can use the following accessories:
1250211
Hose canister with 7.6 m antistatic hose, diam. 205 mm
B
A
13
EN