Explosion protected emergency light fittings ExLin NE+ / ExLin-L NE+
2
Legend
Warning:
This symbol indicates a serious hazard.
Ignoring this warning can result in death or the destruction of the
installation.
Attention:
This symbol indicates a possible failure. Ignoring this warning can
lead to the total failure of the device, system or operation to which it
is connected.
Note:
This symbol stresses important information.
X
Special conditions
ATEX - IEC
This symbol shows Highlights for safe use in accordance to EU-Type-Ex-
amination Certificate/ IEC Ex-Certificate of Conformity.

2.1. Safety instructions

Target group:
For skilled electricians and suitable qualified, instructed
personnel in accordance with national legislation,
including the relevant standards and, where applicable,
in acc. with IEC/EN 60079-14 on electrical apparatus for
explosive atmospheres.
– The light fitting must not be operated in zone 0 and 20 hazardous
areas!
– The light fitting must not be use while excessive deposit of dust
(accd. IEC/EN 60079-31) exist.
– The technical data indicated on the light fitting are to be observed!
– Changes of the design and modifications to the light fitting are not
permitted!
– The light fitting shall be operated as intended and only in undam-
aged and perfect condition!
– Do not keep these operating instructions inside the light fitting
during operation!
The national safety rules and regulations for pre vention of accidents
and the following safety in structions which are marked with an (
in these operating instruction, will have to be observed!
3

Conformity with standards

The explosion protected light fitting ExLin NE+ / ExLin-L NE+ is conform
to the standards specified in the Declaration of conformity, enclosed
separately.
References to standards and directives in these operating instructions
always relate to the latest version. Other additions (e.g. details relating to
the year) shall be observed.
4

Field of application

The light fitting ExLin NE+ / ExLin-L NE+ is suitable for use in zone 1, 2 or
zone 21, 22 hazardous areas acc. to IEC/EN 60079-10-1 and
IEC/EN 60079-10-2.
The materials used, including any external metal parts, are high quality
materials which ensure a corrosion protection and resistance to chemical
substances corresponding to the requirements in a "normal industrial
atmosphere":
- glass-fibre reinforced polyester
- glass-fibre reinforced polyamid
- polycarbonate (status window)
- glass
In case of use in an extremely aggressive atmosphere, you can obtain
information concerning the chemical resistance of the materials used
from your Cooper Crouse-Hinds (CCH) / EATON branch.
5
Application / Properties
The light fitting ExLin NE+ / ExLin-L NE+ is suitable for special operating
conditions such as on offshore platforms or in chemical or pharmaceutical
plants.
The operator is not permitted to modificate the modular light fitting to other
light intensity as original delivered.
The battery pack for the light fitting ExLin NE+ supplies it with energy in the
event of an emergency via the VE + supply unit and a qTEK 300-1 driver.
Both are built into the light fitting ExLin NE+ ex works.
A LiFePO4 battery pack is used as the energy storage device.
At low temperatures, the battery pack is heated with a built-in heater. This
means that the data is retained.
X
The light fitting ExLin NE+ / ExLin-L NE+ have not be used in areas
ATEX - IEC
where intensive electrostatic charging processes may be present.
The data as per point 3 and 4 shall be taken into account with the use.
Applications other than those described are not permitted
without Cooper Crouse-Hinds / EATON's prior written consent.
The instructions stated in section 7 of the operating instructions
shall be observed during operation.
The user alone is responsible for the appropriate use of the light
fitting ExLin NE+ / ExLin-L NE+ in consideration of the basic
conditions existing at the plant (see technical data).
The product is protected by patents. For more information, please contact
your local Cooper Crouse-Hinds / EATON representative.
)