The indicator is on ,but the
compressor doesn't work and
buzzes only
The compressor stops a minute
after start,and restart after a few
minutes,and so repeatedly.
The
compressor
normally,but the temperature in
the cabinet lowers too slowly.
The noise is too loud
The following are not faults:
1) When the freezer is working or after stopping for a while,the refrigerant in
the pipes is cycling and gives out"running water"sounds.
2) The surface temperature of the compressor may be up 70℃~80℃ when it
is working.
3) The back side of step freezer gives out heat.
4) In rainy season, the outer surface of the cabinet may have dew,which
makes no defects on normal use.Just dry it with a piece of cloth.
5) The protective film on the inner tank is to avoid damage during production
The power voltage is too
low.
The power voltage is too
high.
The door is opened too
frequently.
The food in the
cabinet
works
much,and placed
improperly.
The frost film is too thick.
The
surface
condenser is too dirty.
The door seals badly.
The freezer is placed
unstably.
The fixing of the
freezer is loose.
there's contact between
pipes.
is
too
of
the
Put a power-regulater
more than 1000W power
together.
Reduce open times.
Place foods properly
keep place between
them for
ventilation of cold air.
Take out foods
Stop
and
clean
condenser.
Adjust the door seal.
Place it stably.
Tighten the fixing.
Separate them.
the