dc voltage measurement
Set the function switch to the V≅Hz position.
The device will automatically set to DC voltage
measurement.
Connect the red measuring wire to the
V•Ω•CAP• TEMP • HZ connector and the black
one to the COM connector.
Connect the end of the measuring wires to the
measured circuit.
Read the display.
true rmS ac voltage measurement
Set the function switch to the V≅Hz position.
Press the MODE buttonto select the AC Volt
range.
Connect the red measuring wire to the
V•Ω•CAP• TEMP • HZ connector and the black
one to the COM connector.
Connect the end of the measuring wires to the
measured circuit. Read the display.
note: press the peak button to hold the maximum and
minimum measured values in the ac current range.
resistance measurement
Set the function switch to the
Connect the red measuring wire to the
V•Ω•CAP• TEMP • HZ connector and the black
one to the COM connector.
Touch the end of the wires to the outputs of
the measured device
Read the display
Warning! Before starting the measurement
always make sure that the measured circuit is
not under voltage!
capacity measurement
Set the function switch to the CAP position.
Connect the red measuring wire to the
V•Ω•CAP• TEMP • HZ connector and the black
one to the COM connector.
Touch the end of the wires to the outputs of
the measured device
Read the display
note:
the device only does automatic capacity measurement.
Warning! to avoid damage to the device, always make
sure that the measured device is not under voltage and
all capacitors have been discharged.
Warning! discharge high capacity capacitors with
a proper resistor and make sure that it is not under
voltage with a dc voltage measurement.
frequency measurement
Set the function switch to the V≅Hz position.
Press and hold the MODE button for 3 seconds
to select Frequency measurement.
Connect the red measuring wire to the
V•Ω•CAP• TEMP • HZ connector and the black
one to the COM connector.
Touch the end of the wires to the outputs of
the measured device
note: the device only performs automatic frequency
measurement
temperature measurement
Set the function switch to the TEMP position.
The device will automatically switch to °C
measurement.
Connect the white temperature adapter to the
V • Ω • CAP • TEMP • HZ and COM connectors.
Make sure that the „-" adapter cable is
connected to the COM connector and the
„+" is connected to the V • Ω • CAP • TEMP • HZ
connector.
Connect the K-type cable to the adapter of the
device and measure the temperature at the
desired area.
position.
Read the result from the screen.
To switch between measuring modes (°C/°F)
use the MODE button.
note: the device will show an error when you try to set it
to automatic measuring range.
diode test
Set the function switch to the
Press the MODE button to select Diode
measurement.
Connect the red measuring wire to the
V•Ω•CAP• TEMP • HZ connector and the black
one to the COM connector.
Touch the end of the wires to the outputs of
the measured device. Read the display
note: if you switch the connections of the cables through
the diode, the display will show ol. normal values are
between 0,4 - 0,9v.
continuity test
Set the function switch to
Press the MODE button for selecting continuity
measurement.
Connect the red measuring wire to the
V•Ω•CAP• TEMP • HZ connector and the black
one to the COM connector.