Connect 1 fan
Analogue: connects Analogue In (3) and Gnd
(4) to the regulator (input impedance 95kΩ).
Check the jumper settings on the MCA
By default, the jumper settings are set to overrule the digitally controlled I-fan units via the I/O network (1-10V). To
overrule the analogue control I-fan units, the jumper settings must be changed to 0-10V / 10-0V. Do this as follows:
1.
Replace the jumper with resistance with the jumper delivered as a standard.
2.
Set the jumper to the proper position:
Set the I/O address
Using the table on the following pages, set an I/O address with the dipswitches on the <rgeg g sdf gprod> motor.
Gndfi
Connect multiple fans
Analogue: connects Analogue Out (5) and
Gnd (4) to the connection box at the fan(s).
g
7