XV-DW100U, PG-C30XU/XE
XG-P10XU/XE, XG-V10WU/WE
SUPPLEMENT
• Grid button
Change "ON/OFF" of the indication of the color irregularity correction frame.
• Data button
Change "ON/OFF" of the indication of the color irregularity correction data.
• Color select combo box
Select the color that a color irregularity correction is done from R, G, B.
• Level select combo box
Select the gradation level that a color irregularity correction is done.
• Apply button
The data on the changed block are transmitted in the projector.
• Smoothing button
Smoothing the data on the all screens of the color and the level selected at present.
• Exit button
Finish color irregularity correction software. Be sure to write all data in the projector when modifying data.
The PC asks whether the data being edited at present are saved. Just in case, save data.
• Status area
Display the condition and a result of the command .
5-7. Correction procedure
There are the following three kinds of start processes in the correction.
(1)Correct color irregularity based on the data on the projector.
(2)Correct color irregularity based on the data which saved in the file.
(3)Correct color irregularity from the initial value. (There are no correction data.)
Usually, begin with (1).
Begin with (2) when the correction data saved in the file.
Begin with (3) when the occurrence tendency of the color irregularity changes at all by having replaced a panel and/
or the other parts. Begin in this case after reading the file of the initial value data.
Initial value data file name
2d_init.dat
3d_init.dat
Explain the following, a correction process.
<When a panel and a lamp are replaced and correction is necessary.>
With a new lamp set up, this correction is necessary only when the optical axis fails to adjust properly.
1. Push "Connect" button, and connect PC and a projector. After "Auto sync" is finished, the model name of the
projector connected with the status area is displayed. When failed in the connection, ascertain that the connection
of the RS232C cable and the power supply of the projector are in, and restart software again, and push Connect
button again.
XG-P10XU/XE, PG-C30XU/XE, XG-V10WU/WE
Figure 2. The condition that a projector and PC are connected.