Electrical data
Field
Display
Display
Electrical connection
Electrical connection DC voltage supply
Network:
System bus (CAN)
Memory
Interfaces
te aces
2.2.1
Features of the keypad
Pages
Help
Help messages
Information messages
Bit password
Dynamic texts (with bit group structure, single bit
structure or value structure)
Online languages
Programmable keys
Variables
a ab es
1)
Guide value limited by project size
32
Type
Display format
Visible size
Lines x characters
Character size
Character size in text mode
Fonts
Contrast setting
Background light
Power consumption
Fusing
Protocol
Communication medium
Network topology
System bus devices
Max. number of devices
Baud rate [kBit/s]
Max. bus length [m]
User program
Serial
ASP8 (Minidin 8 pole socket) RS232
EDBEPM-H310 DE/EN/FR 2.0
Values
LCD
Text
73.5 x 11.5 mm
2 x 20
3.2 x 5.5 mm
5 x 7 pixels
ASCII, Katakana
Trimming potentiometer
LED
+18 ... 32 VDC
5 W at 24 VDC
Miniature fuse ∅ 5 x 20 mm, 315 mA / F
CANopen
(CAL-based communication profile DS301)
DIN ISO 11898
Line (terminated at both ends with 120 Ω )
Master or slave
63
20
50
125
250
2500
1000
500
250
48 kB
[Number]
[Number]
[Number]
[Total/active at the same time]
[bit]
[Number]
[Number]
[Number]
[Number per page]
[Format]
500
1000
80
25
127
127
128
128/128
8
1)
1024
4
5
5
DEC, HEX, BIN,
BCD, floating point
L