L-force controls, hmi with windows ce, hmi für visualisierung; mit steuerungstechnik (33 Seiten)
Inhaltszusammenfassung für Lenze EPM-H310
Seite 1
DATASHEET LENZE EPM-H310 OTHER SYMBOLS: EPMH310, EPM H310, EPM-H310 RGB ELEKTRONIKA AGACIAK CIACIEK SPÓŁKA JAWNA Jana Dlugosza 2-6 Street 51-162 Wrocław www.rgbelektronika.pl Poland biuro@rgbelektronika.pl +48 71 325 15 05 www.rgbautomatyka.pl www.rgbautomatyka.pl www.rgbelektronika.pl...
Seite 2
YOUR PARTNER IN MAINTENANCE Repair this product with RGB ELEKTRONIKA ORDER A DIAGNOSIS LINEAR ENCODERS SYSTEMS INDUSTRIAL COMPUTERS ENCODERS CONTROLS SERVO AMPLIFIERS MOTORS MACHINES OUR SERVICES POWER SUPPLIERS OPERATOR SERVO PANELS DRIVERS At our premises in Wrocław, we have a fully equipped servicing facility. Here we perform all the repair works and test each later sold unit.
Seite 3
EDBPM−H310 .?$K Betriebsanleitung Operating Instructions Instructions de mise en service Help Info shift EPM−H310 Bedieneinheit Operating unit Unité de commande...
Seite 4
Lesen Sie zuerst diese Anleitung, bevor Sie mit den Arbeiten beginnen! Beachten Sie die enthaltenen Sicherheitshinweise. Please read these instructions before you start working! Follow the enclosed safety instructions. Veuillez lire attentivement cette documentation avant toute action ! Les consignes de sécurité doivent impérativement être respectées.
Seite 5
Help Info shift LCD ADJ INPUT: 18 - 32 V 5W FUSE 315 mA +24 VDC 0 VDC N.C. ASP8 1 2 3 4 5 h310_014...
Legende zur Übersicht Pos. Beschreibung Funktion Klemmenleiste 4−polig DC−Spannungsversorgung 24 V Trimmer LCD ADJ Display−Kontrast einstellen Minidin−Buchse 8−polig Serieller Port (ASP) für PC oder SPS Klemmenleiste 5−polig Systembus (CAN) EDBPM−H310 DE/EN/FR 7.1...
Seite 7
Diese Dokumentation ist gültig für ..die Bedieneinheit EPM−H310 ab der Typenschildbezeichnung: EPM−H310 Produktreihe Bedieneinheit Hardwarestand Softwarestand EDBPM−H310 DE/EN/FR 7.1...
TD23 Umfirmierung 00418421 08/2001 TD23 Komplette Überarbeitung zur Serie 00414158 03/2000 TD23 Erstauflage zum Feldtest 0Abb. 0Tab. 0 Tipp! Dokumentationen und Software−Updates zu weiteren Lenze Produkten finden Sie im Internet im Bereich "Services & Downloads" unter http://www.Lenze.com EDBPM−H310 DE/EN/FR 7.1...
Vorwort und Allgemeines Über diese Betriebsanleitung Vorwort und Allgemeines Mit der Bedieneinheit EPM−H310 können Sie auf Codestellen von Lenze Antriebs- reglern, Servo PLC 9300 und Drive PLC zugreifen und diese auf komfortable Weise steuern. Die Kommunikation erfolgt über Systembus (CAN).
Vorwort und Allgemeines Verwendete Hinweise Verwendete Hinweise Um auf Gefahren und wichtige Informationen hinzuweisen, werden in dieser Do- kumentation folgende Piktogramme und Signalwörter verwendet: Sicherheitshinweise Aufbau der Sicherheitshinweise: Gefahr! (kennzeichnet die Art und die Schwere der Gefahr) Hinweistext (beschreibt die Gefahr und gibt Hinweise, wie sie vermieden werden kann) Piktogramm und Signalwort Bedeutung...
Technische Daten Allgemeine Daten und Einsatzbedingungen Technische Daten Allgemeine Daten und Einsatzbedingungen Allgemeine Daten Konformität und Approbation Konformität 2004/108/EG EMV−Richtlinie Approbation cULus Underwriter Laboratories Inc. (File−No. E189179) Personenschutz und Geräteschutz Schutzart IP65 (frontseitig) Angewandte Normen EN 61000−6−4 Störaussendung. Nutzungsbeschränkung: Die Einhal- zu Grenzwerten (2007) tung der Schutzanforderungen in Wohngebieten ist...
Technische Daten Elektrische Daten Schnittstellenbeschreibung 2.2.2 Schnittstellenbeschreibung h310_010 Abb. 2−1 ASP8 Minidin 8pol. Buchse Signal Rx RS232 IN Tx RS232 OUT n. c. RTS RS232 OUT CTS RS232 IN n. c. Signal GND +5 VCC (reserved) n.c. Nicht angeschlossen EDBPM−H310 DE/EN/FR 7.1...
Technische Daten Abmessungen Abmessungen Help Info shift h310_001 Abb. 2−2 Abmessungen a [mm] b [mm] c [mm] d [mm] e [mm] 166.0 86.0 27.0 41.0 Einbauausschnitt h312_004 Abb. 2−3 Einbauausschnitt a [mm] b [mm] 77.0 157.0 EDBPM−H310 DE/EN/FR 7.1...
Mechanische Installation Bedieneinheit befestigen Mechanische Installation Bedieneinheit befestigen Die Maße für den Einbauausschnitt entnehmen Sie den technischen Daten. (¶ 15) So befestigen Sie die Bedieneinheit: h310_006 1. Bedieneinheit mit Dichtung in den Einbauausschnitt schieben. U T : I N P N .
Seite 19
Mechanische Installation Bedieneinheit befestigen U T : IN P N . C h310_009 3. Schrauben in die Befestigungsschellen drehen. 4. Schrauben gegen die Einbautafel drehen und festziehen. EDBPM−H310 DE/EN/FR 7.1...
Elektrische Installation Versorgungsspannung anschließen Elektrische Installation Stop! Beschädigung angeschlossener Geräte. Verbinden Sie den ƒ PE−Leiter so wie es in der Abbildung dargestellt ist! Bedieneinheit nur im spannungslosen Zustand verdrahten! ƒ Versorgungsspannung anschließen LCD ADJ INPUT: 18 - 32 V 5W FUSE 315 mA –...
Elektrische Installation Systembus (CAN) verdrahten Systembus (CAN) verdrahten Hinweis! Verbinden Sie nur Klemmen gleichen Signaltyps miteinander. ƒ Weitere Informationen zum Systembus (CAN) finden Sie im ƒ Kommunikationshandbuch CAN. Prinzipieller Aufbau (H310) CAN- Shield CAN+ N.C. CG LO HI CG LO HI CG LO HI CG LO h310_004...
Seite 22
Elektrische Installation Systembus (CAN) verdrahten Klemmenbelegung Stop! Schließen Sie einen 120 W Abschlusswiderstand am ersten und letzten Bus−Teilnehmer an. Klemme Bezeichnung Erläuterung V− Bezugspotential CAN− Systembus LOW (Datenleitung) Shield Schirm des Systembus−Kabels auflegen CAN+ Systembus HIGH (Datenleitung) n. c. Nicht angeschlossen Für einen störungsfreien Betrieb verwenden Sie Leitungen mit der angegebe- nen Spezifikation: Spezifikation der Leitung...
Inbetriebnahme Erstes Einschalten Inbetriebnahme Erstes Einschalten Für die Inbetriebnahme ist eine vollständige Verdrahtung des Systembus not- wendig. Überprüfen Sie vor dem Einschalten der Versorgungsspannung ... die gesamte Verdrahtung auf Vollständigkeit und Kurzschluss, ƒ ob das Bussystem beim physikalisch ersten und letzten Busteilnehmer ƒ...
Inbetriebnahme Projekt in die Bedieneinheit übertragen Bedieneinheit und PC verbinden Projekt in die Bedieneinheit übertragen 5.2.1 Bedieneinheit und PC verbinden Stop! Die Verbindung zwischen PC und Bedieneinheit nur bei ausgeschalteten Geräten herstellen! LCD ADJ INPUT: 18 - 32 V 5W FUSE 315 mA +24 VDC...
Inbetriebnahme Projekt in die Bedieneinheit übertragen Projekt−Download 5.2.2 Projekt−Download Hinweis! Im »HMI Designer« können Sie auswählen, ob mit dem Laden des Projekts gleichzeitig die Firmware aktualisiert werden soll. Die Firmware muss immer beim ersten Download eines Projekts in die Bedieneinheit bzw. nach einem Update des Projektierungstool »HMI Designer«...
Inbetriebnahme Projekt in die Bedieneinheit übertragen Verbindung zum PC entfernen 5.2.3 Verbindung zum PC entfernen So entfernen Sie die Verbindung zum PC: 1. PC ausschalten. 2. Versorgungsspannung für Bedieneinheit abschalten. 3. Programmieradapter EPZ−H111 an der Bedieneinheit und Downloadkabel EPZ−H110 am PC abziehen. 4.
ƒ Die zuletzt aufgetretene Störung (Error) ƒ Sie möchten ... Drücken Sie die Tasten ... Beispiel den Status der Bedieneinheit abfragen. shift Driver: Can Lenze M Ver. : 1.05 die nächste Statusseite anwählen. oder Info Help â á Addr. : NO ADDRESS Error : RESET die Statusanzeige schließen.
<Info> Info−Text aufrufen (Taste programmierbar) shift â Menü−Ebene: Zur nächsten Seite wechseln Info <Pfeil ab> â Parameter−Ebene: Zifferneingabe (9 ... 0 absteigend) Hinweis! Die Funktionstasten (Fx) sind über die Software »HMI Designer« programmierbar. Lenze−Einstellung: Ohne Funktion. ƒ EDBPM−H310 DE/EN/FR 7.1...
Bedienung Daten eingeben Daten eingeben Das Eingeben oder Ändern von Daten ist Schritt für Schritt dargestellt und wird an einem Beispiel erläutert. Sie möchten ... Drücken Sie die Tasten ... Beispiel ein Menü auswählen. shift eine Seite anwählen. oder Info Help â...
Bedienung Informationsmeldung aufrufen Informationsmeldung aufrufen Informationsmeldungen ƒ – sind Texte, die aufgrund eines Ereignisses angezeigt werden können (z. B., wenn ein Istwert eine Grenze übersteigt). – können Sie nur aufrufen, solange das auslösende Ereignis vorhanden ist. – müssen Sie im Projektierungstool »HMI Designer« programmieren. –...
Fehlersuche und Störungsbeseitigung Störungsmeldungen Fehlersuche und Störungsbeseitigung Störungsmeldungen Rufen Sie die Statusmeldungen der Bedieneinheit auf, um die zuletzt aufgetre- tene Störungsmeldung anzuzeigen. (¶ 25) Display Störung Ursache Abhilfe NO ERROR Keine Störung − − PR ERROR Fehlerhafter Verbindung zwischen Bedie- Anschlüsse auf festen Sitz prüfen Datenaus- neinheit und PC ist fehlerhaft...
Wartung Wartung Die Bedieneinheit ist wartungsfrei, wenn die vorgeschriebenen Einsatzbedin- gungen eingehalten werden. (¶ 11) Reinigen Sie die Bedieneinheit mit denaturiertem Äthylalkohol. ƒ Wenn Sie ein anderes Reinigungsmittel verwenden müssen, um ƒ Verunreinigungen zu beseitigen, beachten Sie die Angaben in der Tabelle im Kap.
Oberfläche beschädigt werden. Die folgende Tabelle zeigt die Beständigkeit der Bedien−Oberfläche (Tastatur, Display, Touch Screen) gegen die genannten Chemikalien. Für die Bedieneinheiten EPM−H5xx und EPM−H6xx bietet Lenze Schutzfolien an, mit einer verbesserten Beständigkeit gegen die genannten Chemikalien. Bedieneinheit EPM−H3xx EPM−H4xx...
Seite 37
Anhang Stichwortverzeichnis EDBPM−H310 DE/EN/FR 7.1...
Seite 38
Key for the overview Pos. Description Function Terminal strip, 4−pole. DC voltage supply 24 V Trimmer LCD ADJ Setting display contrast Minidin 8−pole socket ASP serial port for PC or PLC Terminal strip, 5−pole System bus (CAN) EDBPM−H310 DE/EN/FR 7.1...
Seite 39
This documentation applies to ..EPM−H310 operating units as of the following nameplate data: Type EPM−H310 Product range operating unit Hardware version Software version EDBPM−H310 DE/EN/FR 7.1...
Complete revision of series 00414158 03/2000 TD23 First edition for field test 0Fig. 0Tab. 0 Tip! Documentation and software updates for further Lenze products can be found on the Internet in the "Services & Downloads" area under http://www.Lenze.com EDBPM−H310 DE/EN/FR 7.1...
Seite 41
Contents Preface and general information ........About these Operating Instructions .
Seite 42
Contents Maintenance ........... . . Appendix .
Preface and general information About these Operating Instructions Preface and general information The EPM−H310 operating unit enables you to access codes of Lenze controllers, 9300 Servo PLCs and Drive PLCs and to control them easily. Communication takes place via the system bus (CAN).
Preface and general information Notes used Notes used The following pictographs and signal words are used in this documentation to indicate dangers and important information: Safety instructions Structure of safety instructions: Danger! (characterises the type and severity of danger) Note (describes the danger and gives information about how to prevent dangerous situations) Pictograph and signal word...
Technical data General data and operating conditions Technical data General data and operating conditions General data Conformity and approval Conformity 2004/108/EC EMC Directive Approval cULus Underwriter Laboratories Inc. (File no. E189179) Protection of persons and equipment Enclosure IP65 (front) Applied standards for EN 61000−6−4 Noise emission.
Technical data Electrical data Electrical data Field Values Display Type Display format Text Visible size 73.5 × 11.5 mm Lines × Characters 2 × 20 Character size 3.2 × 5.5 mm Character size in text mode 5 × 7 pixels Fonts ASCII, Katakana Contrast setting...
Technical data Electrical data Features of the operating unit 2.2.1 Features of the operating unit Description Values Automatic operations [Number] Backup/restore [Function] available End project Display project information Commands [Function] available Display sequence directory Change language Bit password [Bit] Direct command with value [Function] available structure...
Seite 48
Technical data Electrical data Features of the operating unit Description Values Numeric variables (DEC, HEX, Variables [Number per page] BIN, BCD) guide value limited by the project size EDBPM−H310 DE/EN/FR 7.1...
Technical data Electrical data Interface description 2.2.2 Interface description h310_010 Fig. 2−1 ASP8 Minidin socket, 8−pin Signal Rx RS232 IN Tx RS232 OUT n.c. RTS RS232 OUT CTS RS232 IN n.c. Signal GND +5 VCC (reserved) n.c. not connected EDBPM−H310 DE/EN/FR 7.1...
Technical data Dimensions Dimensions Help Info shift h310_001 Fig. 2−2 Dimensions a [mm] b [mm] c [mm] d [mm] e [mm] 166.0 86.0 27.0 41.0 Mounting cutout h312_004 Fig. 2−3 Mounting cutout a [mm] b [mm] 77.0 157.0 EDBPM−H310 DE/EN/FR 7.1...
Mechanical installation Attaching operating unit Mechanical installation Attaching operating unit The dimensions for the mounting cutout can be found in the "Technical data" (¶ 48) How to mount the operating unit: h310_006 1. Insert operating unit with seal into the mounting cut−out. U T : I N P N .
Seite 52
Mechanical installation Attaching operating unit U T : IN P N . C h310_009 3. Insert screws into mounting clamps 4. Tighten the screws against the mounting board. EDBPM−H310 DE/EN/FR 7.1...
Electrical installation Supply voltage connection Electrical installation Stop! Damage of units connected. Connect the PE conductor as shown ƒ in the figure! Wire the operating unit only when no voltage is applied! ƒ Supply voltage connection LCD ADJ INPUT: 18 - 32 V 5W FUSE 315 mA –...
Electrical installation Wiring of the system bus (CAN) Wiring of the system bus (CAN) Note! Only connect terminals of the same signal type. ƒ For further information with regard to the system bus (CAN) ƒ please refer to the CAN Communication Manual. Principle structure (H310) CAN-...
Seite 55
Electrical installation Wiring of the system bus (CAN) Terminal assignment Stop! Connect a 120 W terminating resistor to the first and last bus device. Terminal Identification Explanation V− Reference potential CAN− System bus LOW (data line) Shield Connect the shield of the system bus cable CAN+ System bus HIGH (data line) n.c.
Commissioning Initial switch−on Commissioning Initial switch−on Commissioning requires a complete wiring of the system bus. Before switching on the supply voltage, check ... the complete wiring for completeness and short circuit, ƒ whether the bus system is terminated at the first and last physical node. ƒ...
Commissioning Project transfer to the operating unit Connecting operating unit and PC Project transfer to the operating unit 5.2.1 Connecting operating unit and PC Stop! Only connect PC and operating unit when the units are switched off! LCD ADJ INPUT: 18 - 32 V 5W FUSE 315 mA +24 VDC...
Commissioning Project transfer to the operating unit Project download 5.2.2 Project download Note! In the »HMI Designer« you can select whether you want to update the firmware at the time the project is loaded. The firmware must always be updated with the first download of a project to the operating unit or after an update of the »HMI Designer«...
Commissioning Project transfer to the operating unit Disconnecting from the PC 5.2.3 Disconnecting from the PC How to disconnect from the PC: 1. Switch off the PC. 2. Switch off the supply voltage for the operating unit. 3. Unplug the EPZ−H111 programming adapter from the operating unit and the EPZ−H110 download cable from the PC.
The last error ƒ If you want to ... Press keys ... Example query the status of the operating unit shift Driver: Can Lenze M Ver. : 1.05 select the next status page Info Help â á Addr. : NO ADDRESS...
Menu level: Go to next page Info <Down arrow> â Parameter level: Input of digits (9 ... 0 descending) Note! The function keys (Fx) can be programmed using the »HMI Designer« software. Lenze setting: Without function. ƒ EDBPM−H310 DE/EN/FR 7.1...
Operation Data input Data input Data input and data modification are described step−by−step using examples. If you want to ... Press keys ... Example select a menu. shift select a page. Info Help â á place the cursor on the previous or next field. Field 1 ß...
Operation Calling up information messages Calling up information messages Information messages ƒ – are texts which can be indicated after a certain event (e.g. if an actual value exceeds a limit). – can only be called up as long as the triggering event is active. –...
Troubleshooting and fault elimination Fault messages Troubleshooting and fault elimination Fault messages Call up the status messages of the operating unit to display the fault message that occurred last. (¶ 58) Display Fault Cause Remedy NO ERROR No fault − −...
Maintenance Maintenance The operating unit is maintenance−free if all operating conditions described in these Instructions are observed. (¶ 43) Clean the operating unit with denatured ethyl alcohol. ƒ If you use any other cleaning agents, please observe the information ƒ given in the table in chapter 9.1.
The following table shows the resistance of the surfaces (keyboard, display, touchscreen) to the listed chemicals. For EPM−H5xx and EPM−H6xx operating units, Lenze offers protective foils with an improved resistance against the listed chemicals. Operating unit EPM−H3xx...
Seite 67
Appendix Chemical resistance Operating unit EPM−H3xx EPM−H4xx EPM−H5xx With protective EPM−H6xx foil Substance Substance ³ 30 % Phosphoric acid Pickling solution Concentrated Pure acetic acid ³ 2 % Sodium hydroxide ³ 50 % Sodium hydroxide ³ 50 % Sulphuric acid Toluol Trichloroethylene EPM−H3xx...
Appendix Index Index Ambient conditions, Climatic, 43 Fault messages, 62 Attaching operating unit, 49 General data, 43 Baud rate, System bus (CAN), 44 Help messages, 61 Cable resistance (CAN), 53 Human Machine Interface, 41 Cable type (CAN), 53 Humidity, 43 Capacitance per unit length (CAN), 53 Chemical resistance, 64 Information messages, 61...
Seite 69
Appendix Index Project − Download, 56 Notes, definition, 42 − Project transfer to the operating unit, 55 Operating conditions, 43 Safety instructions − Ambient conditions, Climatic, 43 − definition, 42 − Humidity, 43 − layout, 42 − Mounting conditions, Weight, 43 Status messages, 58 Operating unit Switch on, initial, 54...
Seite 70
Légende Pos. Description Fonction Bornier à 4 bornes Alimentation 24 V CC Trimmer LCD ADJ Réglage du contraste Prise Minidin à 8 broches Port série ASP pour PC ou API Bornier à 5 bornes Bus Système CAN EDBPM−H310 DE/EN/FR 7.1...
Seite 71
Validité : Unité de commande EPM−H310 à partir de la version ci−dessous (voir plaque signalétique): Type EPM−H310 Série d’appareils Unité de commande Version matérielle Version logicielle EDBPM−H310 DE/EN/FR 7.1...
TD23 Première édition pour essais sur le terrain 0Fig. 0Tab. 0 Conseil ! Les mises à jour de logiciels et les documentations relatives aux produits Lenze sont disponibles dans la zone "Téléchargements" du site Internet : http://www.Lenze.com EDBPM−H310 DE/EN/FR 7.1...
Seite 73
Sommaire Avant−propos et généralités ........Comment utiliser ces instructions de mise en service .
Seite 74
Sommaire Maintenance ........... . . Annexe .
Avant−propos et généralités L’unité de commande EPM−H310 permet d’accéder aux codes des variateurs de vitesse Lenze, du Servo 9300 PLC et du Drive PLC et de commander ces appareils de façon conviviale. La communication est réalisée via Bus Système CAN.
Avant−propos et généralités Consignes utilisées Consignes utilisées Pour indiquer des risques et des informations importantes, la présente documentation utilise les mots et symboles suivants : Consignes de sécurité Présentation des consignes de sécurité Danger ! (Le pictogramme indique le type de risque.) Explication (L’explication décrit le risque et les moyens de l’éviter.) Pictogramme et mot associé...
Spécifications techniques Caractéristiques générales et conditions d’utilisation Spécifications techniques Caractéristiques générales et conditions d’utilisation Caractéristiques générales Conformité et homologation Conformité 2004/108/CE Directive CEM Homologations cULus Underwriter Laboratories Inc. (File−No. E189179) Protection des personnes et protection de l’appareil Indice de protection IP65 (à...
Spécifications techniques Caractéristiques électriques Caractéristiques de l’unité de commande 2.2.1 Caractéristiques de l’unité de commande Description Données Opérations automatiques [nombre] Sauvegarde/reconstitution [fonction] Fermer le projet Afficher les informations sur le projet Instructions [fonction] Afficher le répertoire de la séquence Modifier la langue Mot de passe binaire [bits] Instruction directe avec...
Seite 80
Spécifications techniques Caractéristiques électriques Caractéristiques de l’unité de commande Description Données Temporisateur [nombre] Variables numériques (DEC, Variables [nombre par page] HEX, BIN, BCD) Valeur approximative limitée par la grandeur process EDBPM−H310 DE/EN/FR 7.1...
Spécifications techniques Caractéristiques électriques Affectation de la prise 2.2.2 Affectation de la prise h310_010 Fig.2−1 Prise ASP8 Minidin à 8 broches Signal Rx RS232 IN Tx RS232 OUT N.C. RTS RS232 OUT CTS RS232 IN N.C. Signal GND +5 VCC (réservé) N.C.
Spécifications techniques Encombrements Encombrements Help Info shift h310_001 Fig.2−2 Encombrements a [mm] b [mm] c [mm] d [mm] e [mm] 166.0 86.0 27.0 41.0 Encoche de montage h312_004 Fig.2−3 Encoche de montage a [mm] b [mm] 77.0 157.0 EDBPM−H310 DE/EN/FR 7.1...
Installation mécanique Montage de l’unité de commande Installation mécanique Montage de l’unité de commande Pour les cotes de l’encoche de montage, se reporter aux Spécifications techniques (¶ 80). Pour fixer l’unité de commande : h310_006 1. Glisser l’unité de commande avec le joint dans l’encoche de montage.
Seite 84
Installation mécanique Montage de l’unité de commande U T : IN P N . C h310_009 3. Introduire les vis dans les colliers de fixation 4. Visser la plaque de montage. EDBPM−H310 DE/EN/FR 7.1...
Installation électrique Raccordement de la tension d’alimentation Installation électrique Stop ! Risque d’endommagement des appareils connectés. Relier ƒ impérativement le conducteur PE conformément à l’illustration ! Ne procéder au câblage de l’unité de commande qu’en l’absence ƒ de tension ! Raccordement de la tension d’alimentation LCD ADJ INPUT: 18 - 32 V 5W...
Installation électrique Câblage du Bus Système CAN Câblage du Bus Système CAN Remarque importante ! Ne relier que des bornes du même type. ƒ Pour plus de détails concernant le Bus Système CAN, se reporter ƒ au manuel de communication CAN. Principe de câblage (H310) CAN-...
Seite 87
Installation électrique Câblage du Bus Système CAN Affectation des bornes Stop ! Raccorder une résistance d’extrémité 120 W sur le premier et le dernier participant au bus. Borne Désignation Explication V− Potentiel de référence CAN− Bus Système LOW (ligne de données) Shield Blindage du câble bus CAN+...
Mise en service Première mise en service Mise en service Première mise en service Pour la mise en service, il est impératif que le Bus Système soit correctement raccordé. Avant la mise sous tension, vérifier ... le câblage dans son intégralité pour éviter un court−circuit, ƒ...
Mise en service Téléchargement d’un projet sur l’unité de commande Etablissement de la liaison entre l’unité de commande et le PC Téléchargement d’un projet sur l’unité de commande 5.2.1 Etablissement de la liaison entre l’unité de commande et le PC Stop ! Ne relier le PC à...
Mise en service Téléchargement d’un projet sur l’unité de commande Téléchargement du projet 5.2.2 Téléchargement du projet Remarque importante ! L’outil de conception "HMI Designer" vous permet de déterminer si le micrologiciel doit être actualisé simultanément au chargement du projet. Il faut toujours procéder à...
Mise en service Téléchargement d’un projet sur l’unité de commande Déconnexion du PC 5.2.3 Déconnexion du PC Pour couper la liaison avec le PC : 1. Mettre le PC hors tension. 2. Mettre l’unité de commande hors tension. 3. Retirer l’adaptateur EPZ−H111 de l’unité de commande et le câble de téléchargement EPZ−H110 du PC.
ƒ dernier défaut en date (Error). ƒ Pour ... appuyer sur les touches ... Exemple connaître l’état de l’unité de commande shift Driver: Can Lenze M Ver. : 1.05 sélectionner la page d’état suivante Info Help â á Addr. : NO ADDRESS Error : RESET fermer l’affichage d’état...
Niveau paramètres : entrer les chiffres (9 à 0 dans l’ordre â BAS> descendant). Remarque importante ! Les touches de fonction (Fx) peuvent être programmées à l’aide du logiciel "HMI Designer". Réglage Lenze : pas de fonction. ƒ EDBPM−H310 DE/EN/FR 7.1...
Utilisation Saisie des données Saisie des données L’ordre chronologique pour la saisie et la modification des données est décrit à l’aide d’un exemple. Pour ... appuyer sur les Exemple touches ... sélectionner un menu shift afficher une page Info Help á...
Seite 95
Utilisation Saisie des données Pour ... appuyer sur les Exemple touches ... modifier une zone de texte dynamique 1. Sélectionner le texte. Info Help â á Feld 1 Feld 2 -9876 2. Valider. – Le curseur passe au niveau menu. EDBPM−H310 DE/EN/FR 7.1...
Utilisation Affichage d’un message d’information Affichage d’un message d’information Les messages d’information ƒ – sont des textes pouvant être affichés suite à un événement (exemple : la valeur réelle a dépassé une limite) ; – ne peuvent être consultés que tant que l’événement déclencheur du message est en cours ;...
Détection et élimination des anomalies de fonctionnement Messages d’erreur Détection des erreurs et élimination des défauts Messages d’erreur Afficher les messages d’état de l’unité de commande pour connaître la dernière erreur en date. (¶ 90) Affichage Erreur Origine Remède NO ERROR Pas d’erreur −...
Maintenance Maintenance L’unité de commande ne nécessite aucun entretien à condition de respecter les conditions d’utilisation prescrites (¶ 75). Il convient de nettoyer l’unité de commande à l’aide d’alcool éthylique ƒ dénaturé. Si cette opération est insuffisante et s’il faut utiliser un autre produit ƒ...
Le tableau suivant montre la résistance aux produits chimiques de l’interface opérateur (clavier, afficheur, écran tactile). Pour les unités de commande EPM−H5xx et EPM−H6xx, Lenze vous propose des protecteurs d’écran avec une résistance améliorée aux produits chimiques mentionnés.
Annexe Index Index Alimentation CC, 76 Ecran, 76 − Réglage du contraste, 90 Electricité, installation, Raccordement de la tension d’alimentation, 83 Bus Système CAN − Câblage, 84 Elimination des défauts, 95 − Vitesse de transmission, 76 Encoche de montage, 80 Capacité...
Seite 102
Annexe Index Montage de l’unité de commande, 81 Spécifications techniques , 75 Terminologie, 73 − Déconnexion de l’unité de commande, 89 Type de câble (CAN), 85 − Etablissement de la liaison entre l’unité de commande et le PC l’unité de commande et le PC, 87 Unité...