D-SUB connector, externally. In combination
with suitable oscilloscopes,
transfered
via
IEEE-488
computer into the oscilloscopes
Data output on request by:
is for default mode. Then although the
switch
settings
(SWI
MATRIX
PRINTER
command
can be transmitted
(with the default
address 11 (hex 0B)) or
RS232 (at 9600 baud) from a computer.
As well
as to the
bidirectional
in cooperation with an external system, the
interface can also control the oscilloscope:
With
a command
via IEEE-488
trigger system of the oscilloscope
GLE mode
can be activated
RESET-Led lights and data capture is started.
After a trigger
event and the end of the
recording, the interface receives the signal
data from the oscilloscope. Those data are
transfered automatically via RS232. In IEEE-
488
mode
the
interface
line on the bus, to signa! the bus controller
that
valid
data
are available.
In the oscilloscope
not active) the signa' data can be taken over
from
the interface
followed
by data transfer
system. It is recommended
signal capture is completed. Then the HOLD
key(s) should be locked to prevent data from
being overwritten by another trigger event.
The interface
can also be set to an automatic
print mode. If the SINGLE pushbutton
the oscilloscope
is depressed,
system is armed (RESET lights) by the
interface START pushbutton. Now a trigger
event causes a print documentation
after that it prepares the oscilloscope trigger
system
to capture
Via the
data
connectors,
transmitted
in binary,
EPSON format to external
data can also be
or RS232
from
memory.
and SW2) are set
output,
the output
via IEEE488
data transfer
or RS232
in SIN-
(armed).
activates
the
SRQ\
normal mode (SINGLE
at any time.
This is
to the external
to wait until the
the trigger
the next event.
data
can
HPGL, PCL and
devices. The con-
nector and the connector
selectable with two rotary switches.
a
The transfer of signal data can be initiated
either
manually
through
an ASCII
received from an external system (e.g. PC)
via the following
IEEE-488
This port is for bidirectional communication
in "device"
or "talk only" mode.
In
"device"
controls interface and oscilloscope
If in "talk
only"
transfered directly to a "listen only" device.
Serial port (RS232, V.24/ V.28, DIN 66020)
the
Data can be transfered via this port in both
The
directions
with
baud. The interface can be controlled by a
computer
receiving or transmitting
that device.
data to an externai device by pushing the
START key.
MATRIX
PRINTER
This port enables the transfer of data to a
suitable
external
CENTRONICS
device must be able to support the format
(e.g. EPSON).
Installation
Please check first that the oscilloscope
corresponds
ditions
(three-conductor
of
protective
earthing contacts on plugs and
oscilloscope).
install the interface. In this case contact your
HAMEG
distributor.
and
be
1.
Switch
disconnect the power connector.
2.
Place the oscilloscope on a soft surface
parameter
(START
pushbutton)
command
connectors:
(GPIB)/
IEC625
mode
a controller
mode,
signal
9600, 4800,
2400
It is also possible to transfer
Port
device
equiped
connector.
The
to the SAFETY CLASS I con-
power cord with
If not, it is not permitted
off the oscilloscope
are
or
which
is
device
data are
or 1200
data to
with
a
external
to
and
19