● Troubleshooting
Problem
The machine does not work, The
battery pack is fully charged and
contact.
The machine broke down suddenly
while it was working
The noise of the machine or the
temperature is too high
The socket comes off easily from
the anvil
For battery tools:
Ambient temperature range during operation and storage: 0℃ - 45℃
Recommended ambient temperature range during charging: 5℃ - 40℃
Model
*The battery packs of our company are constantly updated, please look forward to our service and latest news!
EN
12
Cause
Poor contact between battery pack
and the machine.
Machine parts are damaged.
The battery pack runs out of power
High temperature or overload
protection
Machine parts are damaged.
The gear box is short of lubricating
oil
The machine absorbs dust or iron
filings
Machine parts are damaged.
The socket is worn.
The spiral retaining ring of the anvil
is worn
Charger
FFCL20-02
FFCL20-04
FFCL2040-2
Remedy
Reinstall the battery pack.
Send the machine back to the
original factory or maintenance
point for repair.
Recharge the battery pack or
replace the fully charged battery
pack
Leave the machine and battery
pack to cool
Send the machine back to the
original factory or maintenance
point for repair.
Add special lubricating oil.
Clean the machine.
Send the machine back to the
original factory or maintenance
point for repair.
Send the machine back to the
original factory or maintenance
point for repair
Battery pack
FFBL2020
FFBL2025
FFBL2040
FFBL2050
FFBL2060