Herunterladen Inhalt Inhalt Diese Seite drucken

Elektrischer Anschluss - Electrolux EOB53000 Benutzerinformation

Elektro-einbaubackofen
Vorschau ausblenden Andere Handbücher für EOB53000:
Inhaltsverzeichnis

Werbung

Elektrischer Anschluss

The oven is designed to be connected
to 230-240V~(50Hz) electricity
supply.
The oven has an easily accessible termi-
nal block which is marked as
follows:
Letter L
-
Live terminal
Letter N
-
Neutral terminal
-
Earth terminal
This oven must be earthed!
The cable used to connect the oven to
the electrical supply must
comply to the specifications given be-
low.
elektrischer anschluss electrolux 47
For UK use only
Min.
Connec-
size
tion
Cable/
via
flex
Cooker
2,5 mm
Control
Circuit
It is necessary that you install a double
pole switch between the oven and the
electricity supply (mains), with a mini-
mum gap of 3mm
between the switch contacts and of a
type suitable for the required load in
compliance with the current regulations.
The switch must not break the yellow
and green earth cable at any point.
Important
After installation and connecting, the ca-
ble must be placed so that it cannot at
any point reach a temperature of more
than 50°C above the ambient tempera-
ture.
Before the oven is connected, check
that the main fuse and the domestic in-
stallation can support the load; and that
the power supply is properly earthed.
The manufacturer declines any re-
sponsibility should these safety
measures not be carried out.
Cable/
flex
Fuse
type
2
PVC/PVC
min:
twin and
15A
earth
max:
20A

Werbung

Inhaltsverzeichnis
loading