Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Sales@Akg.com - AKG C451 B Bedienungsanleitung

Reference condenser vocal microphone
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

TEcHNIcAL dATA

7
Technical data
Polar pattern:
Frequency range:
Sensitivity:
Electrical Impedance:
Recommended load
impedance:
Max. SPL for 0.5% THD:
Equivalent noise level to
IEC 60268-4 (A-weighted):
Dynamic range:
Preattenuation Pad:
Highpass filter:
Powering:
Operating temperature:
Connector Type:
Finish:
Dimensions:
Net/shipping weight:
*) Values measured with 48-V phantom power. Reduce by 2 dB for 24-V or
8 dB for 12-V phantom power.
This product conforms to the standards listed in the Declaration of
Conformity. You can request the Declaration of Conformity by e-mail from

sales@akg.com.

28
cardioid
20 to 20.000 Hz ± 1,5 dB from published
curve
9 mV/Pa / - 41 dBV re 1 V/Pa
< 200 ohms
> 1000 ohms
112 Pa / 135 dB SPL (0 dB preattenuation*)
355 Pa / 145 dB SPL (10 dB preattenuation*)
1120 Pa / 155 dB SPL (20 dB preattenuation*)
18 dB(A)
117 dB max. (A-weighted)*)
switchable to 0, - 10, - 20 dB
switchable to flat or 12 dB/octave at 75 Hz
or 150 Hz
9 to 52 V phantom power to IEC 61938
- 20°C to + 60°C
3-pin male XLR
satin nickel plated
dia.: 19 mm (0.7 in.); length: 160 mm (6.3 in.)
125 g (4.4 oz.) / 760 g (1.7 lbs.)
C451 B MANUAL
Frequency response
Polar Diagram
C451 B MANUAL
TEcHNIcAL dATA
29

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading