Figure 1-2. Hard-Drive Indicators
1
drive-status indicator (green and amber)
Table 1-1 lists the drive indicator patterns for RAID hard drives. Different patterns are displayed as drive
events occur in the system. For example, if a hard drive fails, the "drive failed" pattern appears. After the
drive is selected for removal, the "drive being prepared for removal" pattern appears, followed by the "drive
ready for insertion or removal" pattern. After the replacement drive is installed, the "drive being prepared
for operation" pattern appears, followed by the "drive online" pattern.
Table 1-1. Hard-Drive Indicator Patterns for RAID
Condition
Identify drive/preparing
for removal
Drive ready for insertion
or removal
Drive predicted failure
Drive failed
Drive rebuilding
1
Drive-Status Indicator Pattern
Blinks green two times per second
Off
NOTE:
The drive status indicator is also off until all hard drives are
initialized after system power is applied. Drives are not ready for
insertion or removal during this time.
Blinks green, amber, and off.
Blinks amber four times per second.
Blinks green slowly.
2
2
green drive-activity indicator