Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - IKEA FRAMTID HGA5K Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für FRAMTID HGA5K:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ENGLISH
Problem
The gas ring burns unevenly
If there is a fault, first try to find a solution to
the problem yourself. If you cannot find a
solution to the problem yourself, contact the
After Sales Service (refer to the Service
chapter).

Technical data

Hob dimensions
built in height
Class Appliance: 3
Appliance Category: II2E+3+
Appliance gas supply: Natural Gas G20/
G25 (2E+) 20/25 mbar
Type of
Burner
Gas
type
G20/G25
Ultra-
(2E+)
rapid
20/25
(large)
mbar
Rapid
Semi-
rapid
Auxili-
ary
(small)
Possible cause
Burner crown is blocked with
food residues
width
depth
Injec-
Nominal
tors
Power
1/100
kW
mm
146
4.0
119
3.0
96
2.0
70
1.0
Check the main injector is
not blocked and the burner
crown is clear of food parti-
cles.
If you operated the appliance wrongly,
or the installation was not carried out
by a registered engineer, the visit from the
customer service technician or dealer may
not take place free of charge, even during
the warranty period.
This appliance is designed for use with nat-
ural gas but can be converted for use with
other gas type according to table below.
Nomi-
Nomi-
nal
nal
Flow g/
Flow g/
h
h
G30
G31 37
28/30
mbar
mbar
-
-
-
-
-
-
-
-
Remedy
744 mm
510 mm
30 mm
Reduced
by-pass
Power kW
1/100 mm
1.4
0.75
0.45
0.33
9
56
42
32
28

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis