Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN
6
1
5
4
2
3

BATTERY AND CHARGER

Open the battery compartment and insert 2 x NiMH batteries. Plug in the
connector plug and close the battery compartment.
When ON/OFF-LED is flashing batteries have to be recharged.
Use 2 x AA Alkaline batteries alternatively (take care to correct polarity).
HORIZONTAL USE
Set up the instrument on a flat smooth surface
or mount it onto a tripod.
Release compensator clamp, which protects the
instrument from damages during transport, by
turning wheel (1) to ON until stop.
Press ON/OFF button of the keypad. The inst-
rument will level automatically within the self-
levelling range of ± 3°. The laser head starts ro-
tating. Select the rotating speed with button (6)
of the keypad. The LEDs will show the rotating
speed selected: LED H = (600 rpm),
LED M (= 400 rpm), LED L (= 200 rpm).
An audible signal indicates in case the instrument was set up outside of
compensator range of ± 3°. The laser head stops rotating.
14
KEYPAD
1. ON/OFF button
2. ON/OFF LED
3. LED rotating speed high (600 rpm)
4. LED rotating speed medium (400 rpm)
5. LED rotating speed low (200 rpm)
6. Rotating speed switch
VERTICAL USE
For vertical use it is absolutely required to set
the compensator clamp (1) to OFF .
Set up the instrument with its wallmount on
a flat smooth surface or mount it on a tripod
with its 5/8" thread.
Center the vial for vertical application by
means of the foot screw screw (8). Take care
to set vial very precisely as the compensator
will not work in vertical mode.
For the use please see Horizontal use.
NOTE
During transport and in vertical use the compensator clamp must be set to
OFF . Disregard may lead to damage of the unit!
RECEIVER EL 702
SUPPLIED WITH
Receiver EL 702 with clamp, battery
EN
Center the vial
1
15
ECOLINE
3

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading