MOUNTING
1.The pump can be at the same level or below the water tank. lt may be
positioned above the water tank if needed, as it is capable of a
6ft.(1.8m)vertical prime. Horizontal inlet tubing will allow priming to
30ft(9m).
2.Consider a dry location that allows easy access if maintenance is
required. The pumps should not be located in an area of less than one
cubic foot unless adequate ventilation is provided. Excessive heat may
trigger the integral thermal breaker and interrupt operation. When the
temperature drops the breaker will automatically reset and start pro ration.
3.The pump can be mounted in any position, f mounting the pump vertically.
The pump head should be in the down position. The mounting feet are
intended to isolate the pump from the mounting surface: over-tightening,
flattening, or use of oversized screws will reduce the ability to isolate
vibration and noise through the lines.
ELECTRICAL
The pump should be on a dedicated (individual) circuit protected by the
specified fuse indicated on the motor label.A U/L, CE ect approved marine
duty (ignition protected) switch rated at above 15 amps is recommended
and must interrupt current flow on the positive(+red)lead.The pump must
be grounded to a known ground (battery). The ground wire must be the
same size (gauge/Mm2) as the positive
wire.Wire Sizing: Proper wire sizing is required for good pump operation. If
the wire is too small, low voltage will affect the pump performance and can
create a fire hazard.
- 4 -