Smart Modul V2 Top für ProGrid
8. MODBUS-PARAMETER
Modbus-Model of
Modbus PDU
data
Address (16bit)
(DI = Digital inputs/
IP= Input registers)
30000 DI
30001 DI
30002 DI
30003 to 30499
DI
30501 Coil
30502 to 30999
Coil
31000 IR
31001 IR
31002 IR
31003 IR
31004 IR
31005 IR
31006 IR
31007 IR
31008 to 31499
IR
31500 HR
31501 HR
31502 HR
31503 HR
31504 HR
31505 HR
31506 HR
31507 HR
31508 HR
31509 to 31999
HR
50000 DI
50001 DI
50501 HR
50502 HR
50503 HR
50504 HR
50505 HR
50506 HR
50507 HR
50508 HR
50509 HR
50510 HR
50511 HR
50512 HR
50521 DI
50522 DI
50523 HR
50524 HR
50525 HR
50526 HR
50527 HR
50528 HR
50529 HR
50530 HR
50531 HR
50532 HR
50533 HR
50534 HR
50535 HR
50536 HR
50573 HR
*Excel-Datei der Modbus-Kommunikationstabelle auf Anfrage erhältlich
EP.MERSEN.COM
Designation
(note: with float32 -> HW = high word; LW = low
word)
Status
Reserve
Synchronization
Reserve
Password
Resreve
Last Boot Millis
Last Boot Minute
Last Boot Hour
Last Boot Day
Last Boot Month
Last Boot Year
Firmware version
Hardware version
Reserve
Date/Hour
Date/Hour
Date/Hour
Date/Hour
Time Duration for mean
Modbus Parity
Modbus Baudrate (HW)
Modbus Baudrate (LW)
Modbus Slave address
Reserve
ADDR_FCT_PRIVATE_WIDEBAND_FUNDAMENTAL 0/1
ADDR_FCT_PRIVATE_50HZ_60HZ
ADDR_FCT_PRIVATE_CT_A_PHASE_1
ADDR_FCT_PRIVATE_CT_B_PHASE_1
ADDR_FCT_PRIVATE_CT_A_PHASE_2
ADDR_FCT_PRIVATE_CT_B_PHASE_2
ADDR_FCT_PRIVATE_CT_A_PHASE_3
ADDR_FCT_PRIVATE_CT_B_PHASE_3
//customer configuration
ADDR_FCT_PRIVATE_LIMITE_V
ADDR_FCT_PRIVATE_LIMITE_V_DURATION
ADDR_FCT_PRIVATE_LIMITE_I
ADDR_FCT_PRIVATE_LIMITE_I_DURATION
ADDR_FCT_PRIVATE_MINIMUM_TIME_MESSAGE s
ADDR_FCT_PRIVATE_CALL_MONITORING_TIME
//Firmware update settings
ADDR_FCT_PRIVATE_BOOTLOADER_STATUS
ADDR_FCT_PRIVATE_BOOTLOADER_RESET
ADDR_FCT_PRIVATE_APP_LENGTH_MSB
ADDR_FCT_PRIVATE_APP_LENGTH_LSB
ADDR_FCT_PRIVATE_APP_CHECKSUM_MSB
ADDR_FCT_PRIVATE_APP_CHECKSUM_LSB
ADDR_FCT_PRIVATE_APP_DATA_OFFSET_MSB
ADDR_FCT_PRIVATE_APP_DATA_OFFSET_LSB
ADDR_FCT_PRIVATE_APP_DATA1
ADDR_FCT_PRIVATE_APP_DATA2
ADDR_FCT_PRIVATE_APP_DATA3
ADDR_FCT_PRIVATE_APP_DATA4
ADDR_FCT_PRIVATE_APP_DATA5
ADDR_FCT_PRIVATE_APP_DATA6
ADDR_FCT_PRIVATE_APP_DATA7
ADDR_FCT_PRIVATE_APP_DATA8
//Temperature
//Threshold
ADDR_FCT_PRIVATE_TEMP_THRESHOLD
V2-20250410 - Benutzerhandbuch - Smart Modul V2 TOP
Access
Status
Data type
(R = read;
Min/Max-value Preset value
W = write)
0/1
BS1
R
-
0/1
BS1
R
-
-
BS1
W
-
ms
uInt16
R
0 to 59999
min
uInt16
R
0 to 59
Hour
uInt16
R
0 to 23
Day
uInt16
R
1 to 31
Month
uInt16
R
1 to 12
Year
uInt16
R
20 to 99
uInt16
R
0 to 65535
uInt16
R
0 to 65535
W/R
W/R
W/R
W/R
min
uInt8
W
1 to 60
0= none
1= even
-
W/R
2=odd
19200
38400
57600
Bit/s
W/R
115200
19200
38400
57600
Bit/s
W/R
115200
-
W/R
1 to 247
BS1
W/R
0 to 1
0/1
BS1
W/R
0 to 1
-
UINT16
W/R
1 to 65535
-
-
UINT16
W/R
1 to 65535
-
-
UINT16
W/R
1 to 65535
-
V
UINT16
W/R
0 to 65535
s
UINT16
W/R
0 to 65535
A
UINT16
W/R
0 to 65535
s
UINT16
W/R
0 to 65535
UINT16
W/R
1 to 6000
s
UINT16
W/R
1 to 3600
0/1
BS1
R
0 to 1
1 BS1
W
-
UINT16
W
0 to 65535
-
UINT16
W
0 to 65535
-
UINT16
W
0 to 65535
-
UINT16
W
0 to 65535
-
UINT16
W
0 to 65535
-
UINT16
W
0 to 65535
-
UINT16
W
0 to 65535
-
UINT16
W
0 to 65535
-
UINT16
W
0 to 65535
-
UINT16
W
0 to 65535
-
UINT16
W
0 to 65535
-
UINT16
W
0 to 65535
-
UINT16
W
0 to 65535
-
UINT16
W
0 to 65535
°C
INT16
W/R
60 to 90
27
BENUTZERHANDBUCH
Comments
1= no error
-
0 = error
1 = No synchronization in the last 24H
-
0 = Synchronized
-
1 = Password is reset to the default value
0
0
0
1
1
20
-
MSB = major / LSB = minor (0x0103 = 1.3)
-
MSB = major / LSB = minor
5 1, 5 or 10 min; t applies to all mean values
1
19200
19200
247
//choice 0 = wideband active power or 1 =
0
fundamental
0 //choice 0 = 50H or 1 = 60Hz
//CT value = I primary / I secondary x 10 (see CT
-
parameter sheet as reference)
//not use
//CT value = I primary / I secondary x 10 (see CT
-
parameter sheet as reference)
//not use
//CT value = I primary / I secondary x 10 (see CT
-
parameter sheet as reference)
//not use
65535 voltage threshold
255 duration voltage threshold
65535 current threshold
255 duration current threshold
2 minimum duration time to display alerte message
10 Modbus message missing alerte time
0 = application
1 = bootloader
1
1 = to launch bootloader
firmware size MSB
firmware size LSB
firmware CRC32 MSB
firmware CRC32 LSB
write offset MSB
write offset LSB
firmware data
firmware data
firmware data
firmware data
firmware data
firmware data
firmware data
firmware data
90 threshold temperature value