Herunterladen Inhalt Inhalt Diese Seite drucken

Meec tools 021743 Bedienungsanleitung Seite 67

Mähroboter smart
Vorschau ausblenden Andere Handbücher für 021743:
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 75
counterclockwise direction. Refer to
figure 16.
The charging station can be placed next to
a shed or house wall. Position the
charging station where there is at least 1
m of straight perimeter wire with no
obstacles in front of the charging station.
The mains adapter should be mounted on
a wall, at least 30 cm off the ground. The
low voltage cable should be laid outside
the mowing area, if possible. If it is
necessary to lay the cable partly or
completely inside the mowing area, the
cable must be buried.
FIG. 1
FIG. 2
1.
Strip approx. 10 mm of insulation off one
end of the perimeter wire.
FIG. 3
2.
Connect the perimeter wire to one of
the terminals. The red terminal (A) is the
system's OUT direction. Pull the connected
perimeter wire through the opening in the
charging station base plate. Lay out the
perimeter wire and peg it to the ground
along the edge of the mowing area.
When the perimeter wire has been laid
completely and you are back at the base
station, cut off the excess wire, strip 10 mm
of insulation off the end of the wire and
connect it to the other terminal. The black
terminal (B) is the system's IN direction.
FIG. 4
INSTALLATION OF PERIMETER WIRE
NOTE:
The maximum permitted length for the
perimeter wire is 300 m.
1.
The perimeter wire should be laid 25 cm
inside the edge of the mowing area – use
the distance gauge to measure this. It
may be necessary to set the pegs closer
together where the ground is uneven.
FIG. 5
FIG. 6
2.
Where the mowing area is crossed by
paths, driveways etc. that are level with
the ground and the mower can travel over
them, the perimeter wire distance can be
reduced from 30 to 8 cm.
FIG. 7
FIG. 8
Protected zones and narrow passages
The perimeter wire can be laid in a loop to
create an island around flower beds, shrubs,
trees, ponds and similar obstacles and zones
where you don't want the mower to go. When
creating an island, the passage for the mower
must be at least 0.8 m wide.
FIG. 9
FIG. 10
Corners
Corners should be laid with obtuse angles (90°
or larger) and the perimeter wire must run
completely straight to the corner from both
sides.
FIG. 11
FIG. 12
Slopes
The robot lawn mower is able to climb slopes
up to 35% (20°) without any problem. Avoid
areas steeper than this. Measure and calculate
as shown below.
FIG. 13
CONNECTING THE CHARGING
STATION TO THE POWER SUPPLY
Insert the mains adapter plug into a
suitable power outlet. If the perimeter
wire is correctly installed, the charging
station status light will be a steady green.
Errors are also indicated by the status
light. See below.
FIG. 14
EN
67
Inhaltsverzeichnis
loading

Inhaltsverzeichnis