Herunterladen Diese Seite drucken

Warm-on TS25 Montageanleitung

Thermostat analog
TS25 Thermostat Analog/
TS25 Thermostat Analog/
TS25 Thermostat Analogique
Mounting steps/Montageschritte/Étapes de montage:
1
1
2 3 4
5 6 7
L
Sensor/
N
Sensor/
Capteur
I
=16 A
max
2
3
1
2
3
Importer: warm-on GmbH
i-Park Tauberfranken 18, 97922 Lauda-Königshofen, Germany
Operation Manual/
Montageanleitung/
Instructions de montage
4
1
5
Parts/Teile/Pièces
Knob/
Drehknopf/
Molette
D
Cover/
Internal frame/
Thermostat/
Abdeckung/
Abdeckrahmen/
Thermostat/
Couvercle
Cadre intérieur
Thermostat
6
Dimension/Diagramm/Dimensions
86mm
80mm
https://www.bodenheizung-24.de/
TS25 Thermostat Analog
Mounting Instructions
This electronic thermostat is designed for installation in a standard wall box.
The temperature can be adjusted between +5°C and +40°C.
An LED indicates when heating is active.
The thermostat is recommended for controlling electric heating systems.
Heating is managed via the floor sensor included in the package.
Technical Data
2
Voltage:
Current:
Power Consumption:
Temperature Setting Range:
Switching Differential:
Ambient Temperature:
Protection Class:
Housing Material:
Floor Sensor:
Important Information
1. Read these instructions carefully. Ignoring the advices can damage the
product or cause а hazardous condition.
2. Check the ratings given in the instructions and on the product to make
sure the product is suitable for your application.
3. Employ only qualified workers for installation and set to operation.
4. After installation is complete, check out product operation as provided
in these instructions.
Caution: Electrical Shock ог Equipment Damage Hazard. Can shock
individuals or reduce equipment lifetime. Disconnect power supply
before manipulation.
Mounting of Floor Sensor
The floor sensor must be installed inside a conduit embedded in the floor.
The conduit should be expanded at the end and placed as high as
possible in the concrete layer.
• The sensor cable can be extended up to 50 meters using a separate
cable for low-voltage signals.
• Do not use conductors from a multi-core cable that powers the heating
system. Voltage interference can disrupt thermostat operation.
• If using a shielded cable, the shield should not be grounded. Instead,
connect it to terminal 7.
• For optimal performance, use a dedicated sensor cable placed in a
separate conduit.
Temperature and Resistance Values of Floor Sensor
Temperature (°C)
5
10
External frame/
Außenrahmen/
20
Cadre extérieur
30
40
Placement of Thermostat
Install the thermostat on a wall where it has free air circulation.
Do not place it near heat sources (sunlight, radiators), drafts (windows or
doors), or on exterior walls.
23mm
50mm
sensor
https://warm-on.com/
Importer: warm-on GmbH
https://warm-on.fr/
i-Park Tauberfranken 18, 97922 Lauda-Königshofen, Germany
Controls
1
Power Switch (I/O):
I – On,
–Off
O
2
Temperature Setting Knob:
Range: 5~40 °C
3
Heating Indicator LED:
AC230V(AC110V / AC24V available)
Red light = Heating is ON
16 A
5 W
5~40 °C
±0.5K
Temperature Setting
-5~50 °C
IP20
The thermostat's scale ranges from +5°C to +40°C.
Flame-retardant PC
A red LED lights up when heating is active.
Thermoplastic rubber NTC
sensor,
(10 k )
Set the thermostat to its maximum setting until the desired room or floor
3 m cable
temperature is reached. Then turn the control knob back until the LED
turns off.
Fine-tune the temperature over the next 1–2 days to suit your preferences.
Thermostat Adjustment
Once the room temperature is stable, you can calibrate the thermostat to
match the actual room temperature.
To do this:
1. Measure the room temperature using an accurate thermometer.
2. Remove the control knob (1).
3. Rotate the shaft (D).
4. Reattach the knob so the temperature line matches the measured value
(see picture 2).
Note: The thermostat is pre-calibrated. Do not rotate the shaft during
installation.
Conformity
The thermostat model "TS25 Thermostat Analog" complies with the
following directives:
• Low Voltage Directive (LVD) 2014/35/EU
• Electromagnetic Compatibility (EMC) Directive 2014/30/EU
• EU RoHS 2 Directive 2011/65/EU
https://warm-on.com/media/DoC_ts25.pdf
Disposal
In accordance with European Directive 2002/96/EU:
Do not dispose of defective electrical devices in household
Resistance ( )
waste.
22 070
17 960
Use designated recycling centers. Contact your local municipal-
ity or district authority for proper disposal options.
12 091
8 312
Proper disposal ensures environmental protection and avoids
5 827
the release of hazardous substances.
Important:
Never release toxic liquids or gases into the atmosphere.
Warranty
The manufacturer guarantees conformity with the product design
description and adherence to the installation and operation manual.
Warranty Period: 2 years from the purchase date.
In case of defects due to manufacturing faults during the warranty period,
the customer is entitled to free rectification.
Exclusions:
• Improper handling or installation
• Tampering by third parties
• Failure to follow the instructions
• Consequential damages
Please retain your proof of purchase. Warranty claims require this
document.
Installation should be carried out by a qualified specialist.
Electrical connection and wiring must be performed by a certified
electrician.
The installation manual and wiring diagram do not replace professional
training.
Damage from incorrect use or mechanical impact is not covered.
Operation Manual
3
1
2
°C
Weee Reg. No: DE14335428
https://warm-on.com/
loading

Inhaltszusammenfassung für Warm-on TS25

  • Seite 1 The conduit should be expanded at the end and placed as high as possible in the concrete layer. The thermostat model “TS25 Thermostat Analog” complies with the • The sensor cable can be extended up to 50 meters using a separate...
  • Seite 2 Conformité pouvant endommager les systèmes. Mettez l’appareil hors tension lors de Konformitätserklärung Les déclarations suivantes confirment que le thermostat référence “TS25 l’installation ou en cas de réparation. Montage des Bodensensors Die folgenden Erklärungen bestätigen, dass die Thermostat-Referenz Thermostat analogique” est conforme à https://warm-on.fr/media/ Die Fühlerleitung des Thermostats muss in einem separaten Leerrohr nach...