Replacing the paper filter bag/
disposal bag
Close the suction connection
Illustration
Close the suction connection, see wet
vacuuming.
Replacing the paper filter bag
Illustration
Release and remove the suction head.
Pull the paper filter bag out towards the
back.
Pull up the locking slide and tightly
close the paper filter bag upon removal.
Dispose of the used paper filter bag in
the closed, dust-proof bag in accord-
ance with legal requirements.
Fit new paper filter bag.
Insert and lock the suction head.
Replacing the disposal bag
Illustration
Release and remove the suction head.
Pull the disposal bag up.
Pull the opening of the disposal bag out
toward the back over the suction sup-
port and seal it tightly.
Tightly seal the disposal bag with clo-
sure strips underneath the opening.
Remove the disposal bag.
Dispose of the used disposal bag ac-
cording to the local provisions.
Attach the new disposal bag.
Place the disposal bag over the con-
tainer.
Insert and lock the suction head.
Cleaning the electrodes
Release and remove the suction head.
Clean the electrodes with a brush.
Insert and lock the suction head.
22
Troubleshooting
DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Note: In case of a failure (e.g. filter break-
age) the appliance must be turned off im-
mediately. The failure must be remedied
before the appliance is put into operation
again.
Suction turbine does not run
Check the receptacle and the fuse of
the power supply.
Check the power cable, the power plug,
the electrodes and the receptacle of the
device.
Turn on the appliance.
Suction turbine turns off
Empty the container.
Suction turbine does not start again
after the container has been
Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.
Clean the electrodes as well as the
space between the electrodes with a
brush.
Suction capacity decreases
Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.
Replace filled paper filter bag.
Replace the filled disposal bag.
Ensure the filter cover properly locks
into place.
Replace the flat pleated filter.
Test the electrical tool connection.
Dust comes out while vacuuming
Illustration
Check/correct the correct positioning of
the flat fold filter.
Replace the flat pleated filter.
– 7
EN
emptied