Replacing the paper filter bag/
disposal bag
Close the suction connection
Illustration
 Close the suction connection, see wet
vacuuming.
Replacing the paper filter bag
Illustration
 Release and remove the suction head.
 Pull the paper filter bag out towards the
back.
 Pull up the locking slide and tightly
close the paper filter bag upon removal.
 Dispose of the used paper filter bag in
the closed, dust-proof bag in accord-
ance with legal requirements.
 Fit new paper filter bag.
 Insert and lock the suction head.
Replacing the disposal bag
Illustration
 Release and remove the suction head.
 Pull the disposal bag up.
 Pull the opening of the disposal bag out
toward the back over the suction sup-
port and seal it tightly.
 Tightly seal the disposal bag with clo-
sure strips underneath the opening.
 Remove the disposal bag.
 Dispose of the used disposal bag ac-
cording to the local provisions.
 Attach the new disposal bag.
 Place the disposal bag over the con-
tainer.
 Insert and lock the suction head.
Cleaning the electrodes
 Release and remove the suction head.
 Clean the electrodes with a brush.
 Insert and lock the suction head.
22
Troubleshooting
DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Note: In case of a failure (e.g. filter break-
age) the appliance must be turned off im-
mediately. The failure must be remedied
before the appliance is put into operation
again.
Suction turbine does not run
 Check the receptacle and the fuse of
the power supply.
 Check the power cable, the power plug,
the electrodes and the receptacle of the
device.
 Turn on the appliance.
Suction turbine turns off
 Empty the container.
Suction turbine does not start again
after the container has been
 Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.
 Clean the electrodes as well as the
space between the electrodes with a
brush.
Suction capacity decreases
 Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.
 Replace filled paper filter bag.
 Replace the filled disposal bag.
 Ensure the filter cover properly locks
into place.
 Replace the flat pleated filter.
 Test the electrical tool connection.
Dust comes out while vacuuming
Illustration
 Check/correct the correct positioning of
the flat fold filter.
 Replace the flat pleated filter.