2. Check condition of cutter blocks and tightness of cutter block bolts.
! Caution: Using loose or cracked cutter blocks may result in injury to operators as
well as damage to unit.
3. Check that the power source is appropriate for the cutter.
Care: If voltage is too high , the motor will burn out. If the voltage is too low,
insufficient power will be generated. Never use DC current.
4. Check that power supply is properly earthed.
! Caution: Failure to earth power supply may result in electric shock to operator.
5. Check that cord is undamaged and that plug is not loose.
! Caution: Cut or abraded covering could result in a short and electric shock to
operator.
If an extension cable is to be used, make sure that it is undamaged and that it is
the proper thickness for the length.

Cable length

Up to 10 m
Up to 15 m
Up to 30 m
Warm-up
In cold weather, warm unit for 30-60 seconds so that the hydraulic oil reaches the
proper viscosity. Pull trigger -switch to extend piston and release when it has
reached its full stroke, Repeat 15-20 times.

Stopper adjustment

The adjustable stopper function to maintain the rebar in the correct position during
cutting and must be properly set for each size of rebar before making a cut.
Screw in stopper to provide sufficient clearance for rebar.
Cable size
- 9 -
110V
AWG
16
14
10
loading