INSTRUCTIONS FOR USE
ISTRUZIONI PER L'USO
- Never unlock and open the battery case during measurements.
- Confirm the function of the equipment with a known source before measuring an unknown voltage source.
- LEDs will only function properly when ambient temperature is between 0 °C and 50 °C.
- When not in use, store the product in a dry place. Do not store the product in hot, humid or unventilated places.
TECHNICAL DATA
VOLTAGE RANGE
VOLTAGE BAR-GRAPH INDICATORS
ACCURACY
RESPONSE TIME
MAXIMUM CURRENT @ 1000V
VOLTAGE RANGE
SYSTEM
VOLTAGE RANGE
PHASE ANGLE
VOLTAGE RANGE
CONTINUITY RESISTANCE
CONDUCTING CURRENT
BATTERY
TEMPERATURE
HUMIDITY
CAT CATEGORY
GS LVD
EMC
IP CODE
POLLUTION LEVEL
10
VOLTAGE MEASUREMENT
6 – 1000V DC
24 – 1000V AC
6/12/24/50/120/230/400/690/1000 V
± (3% + 3) V
< 1s at 90% each voltage time
< 3.5 mA
HIGH VOLTAGE INDICATION
100V – 1000V AC/DC
PHASE ROTATION MEASUREMENT
THREE PHASE
100V – 1000V
120° ± 5°
NON-CONTACT VOLTAGE DETECTION
> 90V AC
CONTINUITY
0 ~ 1.3 MΩ
≤ 5uA
OPERATING ENVIRONMENT
3V (AAA 1.2 x2)
0 ~ 50°C operating
- 10 ~ 60°C stored
Max 85% RH
SAFETY CERTIFICATION
CAT IV 1000V
EN 61243-3
EN 61236-1
IP65
2
EN
I