RF Rx SW868/SW915/SW917/SW922-4W 24VAC/DC
Montage- und Anschlussanleitung / Funk-Empfänger
Mounting and wiring instructions / Wireless receiver
English
Operating
Blink-Code LED 1
mode
Additional functions
Battery
Off
1 – 3 – 1
monitoring
On
1 – 3 – 2
Status
Off
1 – 4 – 1
monitoring
10 s
1 – 4 – 2
100 s
1 – 4 – 3
1,000 s
1 – 4 – 4
10,000 s
1 – 4 – 5
Notice
If only one or both additional functions are activated, no further trans-
mitter can be taught in.
sWave configuration
NOTE
- If a jumper is inserted in the transmitter to set the
status signal, this jumper overwrites the setting
of the receiver.
- The manual remote control (RFHB) does not send
any status telegrams and ignores this option.
- Only battery-operated wireless switches support
the sWave configuration.
LBT (Listen Before Talk)
The wireless behaviour of the sWave wireless switches can be set
here. the LBT can be switched on or off. LBT must be switched on to
deliver switch data reliably. However, the response time is a few mil-
Function
liseconds slower, depending on the radio load.
LBT
(Listen Before Talk)
Relay K3 indicates
undervoltage of
Off
the taught-in and
On (default)
battery-operated
transmitters.
Status signal interval
A regular status telegram can be configured to monitor the wireless
Relay K4 reports a
switches at intervals of 10, 100, 1,000 and 10,000 seconds. The additio-
status error;
nal telegrams reduce the battery life of the wireless switches.
activate the
function only in
combination with
Status signal
»transmitter with
interval
status signal«.
Off (default)
Function: If there
10s
is no status report
100s
from the taught-in
1000s
transmitter, relay
K4 switches to
10000s
alarm after 2.2
times the status
Attention! If the jumper is set to an interval, wireless switches with
time.
hardware jumpers cannot be reconfigured.
Attention! Make
Restore factory settings
sure that the
This option restores the following factory configuration:
taught-in trans-
mitter is set to the
Relay function
correct status sig-
nal time.
Transmitter function
Battery monitoring
Status monitoring
LBT (Listen Before Talk)
Status signal interval
Existing IDs of wireless switches will not be deleted!
Restore factory setting
Cancel
Confirm
7 / 16
LED 1
Function
blink code
2 – 1
Anti-collision switched off
2 – 2
Anti-collision switched on
LED 1
Function
blink code
3 – 1
No status signal
3 – 2
Every 10 s
3 – 3
Every 100 s
3 – 4
Every 1,000 s
3 – 5
Every 10,000 s
Standard
Standard
Off
Off
On
Off
LED 1 blink code
4 – 1
4 – 2