below 140V. When using a 110V/60Hz power supply, an alarm
will be triggered if the voltage drops below 83V. Once the
voltage returns to normal, the alarm will automatically reset.
Overcurrent Protection Prompt: When using a 220V/50Hz
●
power supply, if the input current exceeds 20A and lasts for 5
seconds, an overcurrent protection alarm will be triggered.
Alternatively, when using a 110V/60Hz power supply, if the
input current exceeds 13A and lasts for 5 seconds, an overcur-
rent protection alarm will be triggered. Stop using the equip-
ment and check if the load is too large. If the overcurrent
protection alarm persists after restarting the charging process,
do not continue using the equipment. Please contact our
after-sales support (non-standard detection function).
●
Output Overvoltage Prompt: When the charging voltage
exceeds 19.0V, an output overvoltage alarm will be triggered.
Stop charging and restart the charging process. If the output
overvoltage alarm persists after restarting, do not continue
using the device and contact our after-sales service.
Output Overcurrent Prompt: In programming power mode, if
●
the current exceeds 155A, in forced start mode, if the current
exceeds 405A, or in fast charging mode, if the current exceeds
105A, an output overcurrent alarm will be triggered. Stop
Undervoltage Protection
Overcurrent Protection
Excessive Output Voltage