Alarm
description
discharged, manual intervention may be required to enter
restoration mode and perform restoration treatment on the
battery.
Vehicle Display Mode:
●
The charging voltage can be set within the range of 9.0V to
16.0V. In standby mode, a small current float charge is applied
to the battery. During battery discharge detection, the system
can output a maximum current of 40A to maintain the battery in
a fully charged state. If the set voltage is lower than the battery
voltage, the system will automatically set the charging voltage
to: battery voltage + 2V.
●
Forced Start Mode:
For batteries that have been stored for a long time and have
insufficient battery level, making it impossible to start the
vehicle and causing severe discharge or damage to the
battery, this mode can be selected. In Forced Start Mode, the
device can provide a maximum current of 400A to 450A to
directly support the instantaneous current required to start the
vehicle.
●
Battery Not Connected Prompt: If the battery clamps are
properly connected and the battery voltage is above 9V, but
the system still displays a "Battery Not Connected" prompt, it is
recommended to first remove the battery clamps, clean the
battery terminals, and then reconnect them. If the issue
persists and the system still indicates that the battery is not
connected, please disconnect the power and contact our
after-sales service for further assistance.
●
Temperature Abnormality Prompt: If a "Temperature Abnormali-
ty" prompt appears, first remove the battery clamps without
turning off the device's power switch. Allow the built-in fan to
cool the system. After a short period, when the temperature
lowers, the system will automatically cancel the alarm and
return to the normal interface. If the "Temperature Abnormality"
prompt appears immediately after powering on, even when the
Battery Not Connected
10