Herunterladen Inhalt Inhalt Diese Seite drucken

Programming With The Cs 2 - Märklin 70391 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für 70391:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
Setting the address and the mode of operation with the DIP switches:
• Setting the mode of operation with DIP Switch 10
Switch 10 off = fx (MM) / mfx
Switch 10 on = DCC
• fx (MM)/DCC Setting the address with DIP switches (See
table starting on Page 30)
Please note: Always do settings with the DIP switches when
there is no voltage present. The signal does not recognize the
current switch settings until the voltage is turned on.

Programming with the CS 2

fx (MM)
The CV programming must be done on the programming track.
Only one signal may be connected to the programming track at
a time.
The following CVs can be changed in fx (MM): CV 39, 40, 41, and
42. With CVs 41 and 42 the value must be divided by 4 in fx (MM),
because only the values 0-80 are allowed, for example:
255/4 = 64 (rounded).
During the programming procedure, the signal light will blink.
During programming with the Central Station, by contrast the
signal is switched. After the end of the programming procedure,
the signal is set at "Go".
The signal must be activated once before programming with
the Mobile Station 2. After that, the desired CV settings can be
changed and at the end the signal must be switched again.
The procedure for programming with the 6021 Control Unit can
be found at www.maerklin.de -> Tools & Downloads ->Tech-
nische Informationen.
8
Please see the operating instructions for the control devices in
question for programming with other devices.
DCC
CV programming must be done on the programming track. Only
one signal may be connected to the programming track at a
time.
The light on the signal will blink as a check during the data
transmission.
Please see the operating instructions for the control devices in
question for programming with other devices.
CV for fx (MM) and DCC
With fx (MM) the address can be set only with the DIP switches.
The values in parentheses are factory default settings.
CV Meaning
1
Address 1 - 255
9
Addresses 256 - 2040
39
Slow movement
Medium fast movement
PoM*
Fast movement
Medium fast movement
with bouncing
Fast movement with
bouncing
Medium fast movement
with bouncing of Arm 1
Medium fast movement
with bouncing of Arm 2
Values
1-255 (1) only DCC
0-7 (0)
only DCC
0 (0)
1
2
3
4
5
only with 70411 /
70412
6
only with 70411 /
70412

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

703927041170412