Installation

Burner assembly

Ø a (mm)
Ø b (mm)
c
125 to 140
172 to 184
M8
5
4
6
d
45°
The burner is normally fitted in such a
way that the fan wheel lies at the
bottom. The fan wheel can however
also be fitted pointing upwards. To do
this: loosen the two screws V, rotate TF
by 180°; put back together and tighten
the two screws V.
Burner installation depth and
brickwork
On heaters without a cooled front wall,
unless the boiler manufacturer
indicates otherwise, brickwork 5 as
shown in the illustration is required. The
brickwork must not protrude beyond the
leading edge of the flame tube, and
should have a maximum conical angle
of 60°. The space between the
brickwork and burner should be filled
with an elastic, non-inflammable
insulation material 6. On boilers with
reverse firing, minimum insertion depth
A of the burner tube should be
observed as per the instructions of the
boiler manufacturer.
0305 / 13 010 761A
Fitting the burner
The burner flange 1 is fitted with
elongated slots 2 and can be used for a
hole-circle-∅ of 172-184mm. The fixing
screws are supplied with the burner.
The flange gasket can be used as a
hole template.
Fitting
Attach burner flange 1 to boiler using
the screws supplied.
· Insert burner into flange and rotate in
twist and lock system.
· Tighten the 3 fixing nuts 3.