Optical Path Calibration
1.
The following signs indicates optical path calibration is needed:
1.1
Machine collision occurs, the red indicator starts to dim, or the cutting ability deteriorates, you need to open the Z-axis protective cover, manually
push the laser head to move left and right on the X-axis and up and down on the Y-axis. During the movement, observe whether the red light indicator
spot deviates from the center of the focusing lens. If a deviation occurs, optical path calibration is required;
1.2
When the engraving output energy is uneven across different areas;
1.3
When replacing the CO2 tube optical path needs to be recalibrated.
2.
For optical path calibration method please refer to the calibration video, which is available from the USB drive or official website https://www.atom-
stack.com/pages/hurricane-guide.
07
Focusing Method
1. Auto-Focus:
Press the [Auto focus] button on the control panel, and the machine will
automatically complete the focusing process. Note: For soft materials or when
using the chuck roller accessory, it is recommended to use manual focus.
2. Manual focus:
Rotate the laser head focusing nut until the air nozzle lowers
onto the 8mm thick focusing piece, just touching the focusing
piece.
Auto focus