CHOOSE OPERATING MODE
Choose the desired operating mode for the thermostat
Press
mode changes for each press
Modes:
- Auto
- Comfort (Preset to comfortable temperature)
- Eco (Preset to low temperature to save energy)
- Holiday (Lowers temperature for a number of days)
When changing temperature in
Auto mode, the thermostat will
operate in Manual
untill next
event occurs.
12
ADVANCED SETTINGS (F4)
Access from user menu, select F4 to be displayed – confirm with
U
pper right digits indicate the setting currently being edited.
Large digits in center of display indicate the setting value.
Adjust with
Save and exit
NO.
DESCRIPTION
Sensor application
01
Calibrate room temp.
02
Calibrate floor temp.
03
04
Floor temp. limit
Week type
05
Confirm selection
FUNCTION
DE-
FAULT
01 ~ Combined sensor (floor
limit active)
02 ~ Room sensor
03 ~ Floor sensor
+/- 5.0°C, the calibrated tem-
perature is displayed
+/- 5.0°C, the calibrated tem-
perature is displayed
5 to 60°C
511 ~ 5 weekdays + saturday
+sunday
7 ~ All days different
13
01
0.0 °C
0.0 °C
35 °C
511