PI
NOTE
Equipment that contains refrigerant R290 (propane) must be installed in a room
with a minimum volume of 1m
NOTE
In the event of a refrigerant leakage, the premises must be ventilated immediately
and the products in the affected cabinet disposed of.
NOTE
Disconnected the cabinet from the power supply before replacing the source of
light. Only a qualified technician is allowed to replace a fluorescent tube.
NOTE
Storing flammable or hazardous liquids in the cabinet is strictly prohibited.
2.3. Package
Transport or move the cabinet to its destination site in the original factory packing, whenever
possible. The packaging materials are recyclable.
NOTE
(This applies to cabinets using R290 as refrigerant): do not turn on the power
to the cabinet if you suspect that a refrigerant leakage has occurred during
transportation.
2.4. Transport damage
Unpack the cabinet and check for any sign of damage during transport. Report any damage
immediately to your insurance company, or to the supplier or manufacturer of the cabinet.
2.5. Installing
NOTE
The minimum floor space requirement for one MD2 Euromax cabinet is
15 m
Restrictions sections for more information on equipment containing R290.
1. Release the tape from the air gap stopper and let it fall into a horizontal position.
Version 04/2024
per every 8 grams of R290.
3
in a room with a ceiling height of 3 m or more. See the Warnings and
2
ENGLISH
4