COMPACT 3.0
• Connect or replace the power cable fuse.
• Replace electronic control.
• Check and correct possible bad contacts, breakages or disconnection of the
power cable.
• Connect or replace the electronic control power supply fuse (for access the
internal air distribution panel must be removed).
• Check and correct the position of the connection cables to power supply (Az with
fuse 50A a + and M a -).
!
(If the error persists contact an Authorised Service Centre).
• Check and correct possible bad contacts on terminals or cables of the return air
probe.
• Connect or replace return air probe.
!
(If the error persists contact an Authorised Service Centre).
• Check and correct possible bad contacts on terminals or cables of the anti-icing
probe.
• Connect or replace the anti-icing probe.
!
(If the error persists contact an Authorised Service Centre).
Solution