6. Operation Instruction
Turn the cleaning pump ON pressing pump switch. Wet the sink, parts to be cleaned and any
brushes prior to cleaning; this will prevent grease and dirt from sticking to the surfaces.
The load capacity must not be exceeded:
100 kg for the BIO-CIRCLE GT Compact and 250 kg for the BIO-CIRCLE GT Maxi
Depending on the positioning of the 3-way control valve, cleaning can occur via:
 Washing by means of a versatile jointed hose with nozzle.
 Cleaning with fl ow-through cleaning brush.
 In middle position both outlets are open.
After the cleaning process has ended switch off the pump again.
The unit is equipped with an electronic timer which stops the pump automatically after 30 minutes.
The timer range can be set between 5 and 60 minutes.
Note: Any parts susceptible to corrosion should not be left in the sink after cleaning.
As with all parts cleaners, excess grease and oil should be disposed of prior to washing. Do not
use this unit as a waste dump. Do not introduce disinfectants, solvents, brake fl uid, engine cool-
ant, chlorinated, acidic or alkaline solutions into this system. Do not add water.
The optimal temperature for the activity of microorganisms and therefore for the breakdown of oil
is approx. 41 °C. Therefore leave the unit always switched on.
For optimal activity of microorganisms and thus of the breakdown of oil, it is essential that the
microorganisms have a supply of oxygen. This is why an air sprinkler has to be permanently
switched on, which guarantees the required oxygen supply for the microorganisms. If the unit is
switched off , or fails because of a defect, the result is that the microorganisms become inactive.
If the unit is to be idle for more than two weeks, it is recommended to turn the unit off . Make sure
the surface of the liquid is not covered with oil. If necessary skim off or absorb any accumulation
of oil.