5. Start Up
After removing the packaging, check the casing and control for any possible transport damage.
Should transport damage be detected, do not connect the machine to the mains. Instead report
the damage to the carrier and to Bio-Circle Surface Technology GmbH. The original packag-
ing must be retained. Place the unit in a dry and stable place of your choice. The ground must
be even. If necessary level the ground out with suitable material. Ensure that the drain valve
is closed. Use only the genuine BIO-CIRCLE L Cleaning Liquid. To fi ll to the optimum volume,
100 L respectively 120 L should be required.
Do not overfi ll!
Other cleaning liquids, such as cleaner solvents, disinfectants and alkaline cleaner, for
example must not be used!
Connect the unit to the electricity supply.
Please ensure that the current entry provided by the customer is furnished with an ELCB (Earth
Leakage Circuit Breaker – FI switch).
Note: Do not connect to the power supply with no liquid inside the machine.
The heater starts to warm up the cleaning liquid to operating temperature.
Allow heater to warm BIO-CIRCLE L solution to working temperature for optimal cleaning ef-
fi ciency. When the solution has reached its proper working temperature of approx. 41º C (This
will take approx. 4 hours depending on the initial temperature), periodically, the heater will turn
itself ON.
Never turn off the BIO-CIRCLE unit unless for servicing or longer periods of non-use (more
than two weeks, see chapter 6. Operation instructions). Once the correct temperature has been
reached, the unit is ready for use.
30
On/Off
Power switch Pump