01 | 2023
5.1.3
Electronic connection
•
Electronic connection must follow up local regulations. The supply voltage
must match the details of the nameplate.
Caution: Danger! Electricity!
•
Please must observe the following points:
– The voltage must match the details on the nameplate!
– All the phase conductors of the device must be insulated by an electricl
wire netting.
– Electrical connection should be according to IEC 364 (DIN VDE 0100). For
safety, device should be connected with a30 mA ground fault circuit bre-
aker. (Type B ground fault circuit breaker can make sure it response to the
error when it with DC fault.)
– The machine cannot be operated with a damaged cable. Cable and plug
replacement only permitted to be carried out by customer services or by
experts approved by the distributor.
– Do not use an extension cord! Please observe the distributor instructions
and local regulations, in case of using an extension cord (Minimum inter-
secting surface: 1.5 mm²).
– When laying out the cable, make sure that people cannot trip over it. Do
not allow the cable to pass through sharp corners or hang in the air. Do not
clamp the cable. In addition, the cables must not be placed over high-tem-
perature items and must be protected from oil and corrosive cleaners.
– Do not reach over the cable when touching the device. For connection via
a main plug, the socket must be easily accessible during operation so that
the plug can be disconnected in caseof a fault. Don't plug a wet plug into
socket.
CP60 Forza