THE APPLIANCE MUST BE EARTHED
The hobs are designed to work with alternating current at the
supply voltage and frequency indicated on the rating plate
(situated under the hob or at the end of the instruction booklet).
Make sure that the local supply voltage corresponds to the
voltage indicated on the rating plate.
Connecting the supply cable to the mains electricity
supply
For models supplied without a plug, fit a standard plug,
suitable for the load indicated on the rating plate, onto the
cable and connect to a suitable socket.
To connect directly to the mains supply, a double-pole switch
with a contact separation of at least 3 mm suitable for the
load and complying with current standards and regulations,
must be fitted between the appliance and the mains supply
outlet. The yellow-green earth wire must not be interrupted
by the switch. The supply cable must be in such a position
that no part of it can reach a temperature of 50 °C above
room temperature. For installation above a built-under oven,
the hob and the oven must be connected separately to the
electricity supply both for safety reasons and for easy removal
of the oven if necessary. Do not use adapters or shunts as
they could cause heating or burning.
Before connecting to the power supply, make sure that:
• the limiter valve and the domestic system can withstand
Table 1
BURNER
A. Triple Ring
C.Rapid
B. Semi-rapid
Supply pressure
* At 15°C and 1013 mbar-dry gas
Propane G31
H.s. = 50,37 MJ/kg
Butane G30
H.s. = 49,47 MJ/kg
Methane G20
H.s. = 37,78 MJ/m

Electrical connection

Burners and nozzles specifications

Diameter
Thermal power
(mm)
kW (H.s.*)
Nomin.
130
3.25
100
3.00
75
1.65
3
the load from the appliance (see rating plate);
• the supply system is efficiently earthed according to
standards and laws in force;
• the socket or double-pole switch are easily accessible when
the appliance is installed.
Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow
Blue
Brown
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
Connect the Green & Yellow wire to terminal marked "E" or
or coloured Green or Green & Yellow. Connect the Brown
wire to the terminal marked "L" or coloured Red. Connect the
Blue wire to the terminal marked "N" or coloured Black.
FAILURE TO OBSERVE THE ACCIDENT-PREVENTION
REGULATIONS RELIEVES THE MANUFACTURER OF ALL
LIABILITY.
Replacing the cable
Use a rubber cable of the type H05RR-F with a suitable
cross section 3 x 0.75 mm². The yellow-green earth wire
must be 2-3 cm longer than the other wires.
Liquid gas
By-pass
Injector
1/100
1/100
Reduc.
(mm)
(mm)
1.3
57
91
0.7
40
86
0.4
30
64
Nominal
Minimum
Maximum
This appliance conforms with the following European
Economic Community directives:
-
73/23/EEC of 19/02/73 (Low Voltage) and subsequent
modifications;
-
89/336/EEC of 03/05/89 (Electromagnetic Compatibility) and
subsequent modifications;
-
90/396/EEC of 29/06/90 (Gas) and subsequent
modifications;
-
93/68/EEC of 22/07/93 and subsequent modifications.
16
- Earth
- Neutral
- Live
Natural gas
Flow *
Injector
g/h
1/100
G30
G31
(mm)
236
232
124
218
214
116
120
118
96
28-30
37
20
25
35
45
Flow*
l/h
G20
309
286
157
20
17
25

Werbung